Error message
Description
Possible error reason
Troubleshooting
ER03 +
Steady tone
Permanent Key activation,
interface shut down at 10s
Water or cookware on the glass
above the interface
Cleaning of the
ER 20
Flash - failure
µ C- faulty
Exchange control unit
ER21
Control unit shuts down, caused by
overtemperature, to avoid damage
of the touch control
Control algorithm has reached
overtemperature, because ambient
temperature is to high
Let cooktop cool down, check
temperature isolation to user
interface
ER22
Defective Key evaluation . Control
unit cuts off after 3.5 - 7.5 sec.
Short-circuit or discontinuation in
the range of the key evaluation
Exchange control unit
ER31
Configuration data is wrong
Configuration of the induction
neccessary
New configuration
ER36
NTC value is not within its
specification (value < 200mV or >
4.9V; control unit cuts off
Short-circuit or cut-off at NTC
Exchange control unit
ER40
Secondary voltage is min.5s to
low (1,8V< UPowerfail< 2,9V)
Primary-PTC to hot
Disconnect interface from
power supply
ER47
Communication failure
between induction and Touch
Control
No or incorrect communication Connection cable broken or
incorrect mounted
E2
Overtemperature on the
cooking zone
Let the system cool down
E6
Failure of the power unit
Change power
E7
Unknown mistake
Change induction modul
E8
Fan failure
Fan or control electronics of the
fan are broken
Change induction modul
E9
Broken coil temperature sensor
Change coil sensor
U 400
Secondary voltage of the
power unit to high (primary >
300V).
Control unit cuts off after 1 sec
releasing a permanent tone.
Control unit is wrongly
connected.
Connect to correct mains
voltage
E/A
Error on power board or
supply element
No power supply of the power
element or error on power
board
1. Check wiring
2. Check filter board
3. Replace power board