EN
20
Proper adjustment will produce a stable, steady blue flame
of minimum size.
The final adjustment should be checked by turning knob from
high to low several times without extinguishing the flame.
This adjustment, at low setting, will automatically provide
the proper flame size at medium setting.
After Conversion steps have been completed, check the
appearance of each burner’s flame at the HI and LO
settings, if the flames appear too large or too small review
each step to make sure it was completed correctly.
NOTE: To obtain the correct minimum setting with LP gas,
turn clockwise tightening the valve fully by the thin-
blade screwdriver into the recess at centre of valve
stem.
Electric gas ignition
The gas burner use an electric ignition device located near
each burner that by means a spark igniters ensure its surface
light automatically.
ELECTRIC IGNITION
See Use & Care manual for better explanation and its control.
The Burner Flames
Turn each burner on. Flames should be blue in color with no
trace of yellow. The burner flames should not flutter or blow
away from the burner. The inner cone of the flame should be
between 1/2” and 3/4” long.
BURNER FLAMES
-1/2” to 3/4”
COOKTOP BURNER