6
For Safe Use of the XG2000R
A default login password is set before the XG2000R is shipped. For security reasons, a new
password should be chosen before the XG2000R is used.
CAN/CSA C22.2 No.60950-01,UL60950-1 and EN60950-1
Under certain conditions, twisted pair cables can become charged with static electricity. Con-
necting a statically charged twisted pair cable to a device can cause the device or its LAN
port to operate falsely or to become damaged.
Use a static removal tool to discharge twisted pair cables to ground immediately before con-
necting them to devices.
Note that a discharged twisted pair cable that has been left unconnected for a long time may
become statically charged again.
[Use for the high safety required case]
The XG2000R is designed, developed and manufactured as contemplated for general use,
including without limitation, general office use, personal use, household use, and ordinary
industrial use, but is not designed, developed and manufactured for use in situations with
accompanying fatal risks or dangers that, unless extremely high safety is secured, could lead
directly to death, personal injury, severe physical damage or other loss (hereinafter "High
Safety Required Use"), including without limitation, nuclear reaction control in nuclear facility,
aircraft flight control, air traffic control, mass transport control, medical life support system,
and missile launch control in weapon systems.
Do not use the XG2000R for High Safety Required Use without otherwise ensuring the safety
level required. Fujitsu and its related companies assume no liability whatsoever for damages
arising from use of the XG2000R by the user in high-safety applications, and for any claims or
compensation for damages by the user or a third party.
The XG2000R can install a class 1 laser module (XFP module), and can emit invisible laser
light. Do not look into the 10 Gigabit Ethernet port openings. The following warning applies to
the XG2000R’s laser:
• The XG2000R can install XFP modules, which are laser devices.
In the USA, these XFP modules are certified as Class 1 laser products that conform to the
requirements of the Department of Health and Human Services (DHHS) regulation 21 CFR
Subchapter J, and this certification is indicated by a label attached to each XFP module.
Outside the USA, these XFP modules are certified as Class 1 laser products that conform
to the requirements given in IEC60825-1 (2007) and EN60825-1 (2007).