1 .3
Specifications
1
Hydraulic unit : Sound pressure level in (x)m of the device, 1,5m of the
ground, the open field / Outdoor unit : Sound pressure level in (x)m of the
device,middle from the ground of the height of the outdoor unit , the open field.
2
The sound power level is a laboratory measure of the emitted sound power
but contrary to the noise level, it doesn't correspond to the measure of the felt.
3
Refrigerant R410A (as per the standard EN 378.1).
4
Factory charge of refrigerant R410A.
5
Taking into account the possible additional load of refrigeration fluid R410A
(see
Designation models alféa e
5
6
8
10
13
16
Nominal heating performances
(outdoor temperature/ initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system
kW
4,50
6,00
7,50
10,00
14,01
16,06
-7 °C / +35 °C - Floor heating system
kW
4,10
4,60
5,70
7,40
9,45
12,93
+7 °C / +45 °C - Low temperature radiator
kW
4,50
5,10
6,20
8,27
10,43
13,60
-7 °C / +45 °C - Low temperature radiator
kW
4,10
4,45
5,05
7,40
9,25
11,20
+7 °C / +55 °C - Radiator
kW
4,50
4,50
5,0
7,00
7,84
10,03
-7 °C / +55 °C - Radiator
kW
3,70
3,85
5,20
7,00
7,29
8,65
Power absorbed
+7 °C / +35 °C - Floor heating system
kW
1,00
1,41
1,84
2,49
3,50
4,37
-7 °C / +35 °C - Floor heating system
kW
1,47
1,74
2,23
2,97
3,92
5,32
+7 °C / +45 °C - Low temperature radiator
kW
1,31
1,50
1,87
2,53
3,19
4,38
-7 °C / +45 °C - Low temperature radiator
kW
1,86
2,04
2,47
3,70
4,38
5,22
+7 °C / +55 °C - Radiator
kW
1,79
1,79
1,94
2,86
3,25
4,01
-7 °C / +55 °C - Radiator
kW
2,20
2,33
3,34
4,15
4,45
5,20
Coefficient of performance (COP) (+7 °C / + 35 °C)
4,52
4,26
4,08
4,02
4,00
3,68
Electrical characteristics
Supply voltage (50 HZ)
V
230
Maximum current for appliance
A
11
12,5
17,5
18,5
22
25
Nominal current
A
4,5
6,3
8,1
10,9
11,4
14,2
Max. current of the Heating electrical back-ups
A
13,05 / 26,1
Power of the Heating electrical back-ups
kW
ajustable 3 or 6 kW
Real power absorbed by the fan
W
49
49
49
100
2 x 100
2 x 100
Real power absorbed by the circulation pump
W
24
24
24
24
39,5
39,5
Maximum power absorption by the outdoor unit
W
2530
2875
4025
4255
5060
5750
Hydraulic circuit
Maximum operating pressure Heating
MPa (bar)
0,3 (3)
Hydraulic system flow rate 4°C<Δt<8°C
(nominal conditions) mini / maxi
l/h
490 / 980
650 / 1300
810 / 1620
1080 / 2160
1380 / 2760
1720 / 3450
Various
Weight of outdoor unit
kg
41
41
42
60
92
92
Noise level at 1 m
1
(hydraulic unit)
dB (A)
39
Sound power level according to EN 12102
2
(hydraulic unit)
dB (A)
46
Noise level at 1 m
1
(outdoor unit)
dB (A)
41
41
47
47
47
48
Sound power level according to EN 12102
2
(outdoor unit)
dB (A)
63
63
69
69
69
70
Weight of hydraulic unit (empty / full of water)
kg
42 / 58
Water capacity of the hydraulic unit
l
16
Heating system operating limits
Outdoor temperature mini / maxi
°C
-20/+35
-20/+35
-20/+35
-20/+35
-25/+35
-25/+35
Initial max. heating water temperature
Floor heating system
°C
45
Initial max. heating water temperature
Low temperature radiator
°C
55
55
55
55
55
55
Flow min. heating water temperatur
°C
8
Refrigeration circuit
Diameter of "Gas" pipes
inches
1/2
1/2
5/8
5/8
5/8
5/8
Diameter of "Liquid" pipes
inches
1/4
1/4
1/4
3/8
3/8
3/8
Factory charge of refrigerant R410A
3
g
1100
1100
1400
1800
2500
2500
Maximum operating pressure
MPa (bar)
4,15 (41,5)
Minimum / Maximum length of pipes
4
m
5 /15
5 /15
5 /15
5 /15
5 /15
5 /15
Maximum length of pipes
5
/
Maximum level difference
m
30 / 20
30 / 20
30 / 20
30 / 20
20 / 15
20 / 15
Installation and operation manual "1764 - EN"
- 5 -
Air to Water Heat Pump, split system
Designation model Waterstage Comfort
5
6
8
10
Nominal heating performances
(outdoor temperature / initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system
kW
4,50
6,00
7,50
10,00
-7 °C / +35 °C - Floor heating system
kW
4,10
4,60
5,70
7,40
+7 °C / +45 °C - Low temperature radiator
kW
4,50
5,10
6,20
8,27
-7 °C / +45 °C - Low temperature radiator
kW
4,10
4,45
5,05
7,40
Power absorbed
+7 °C / +35 °C - Floor heating system
kW
0,996
1,41
1,84
2,49
-7 °C / +35 °C - Floor heating system
kW
1,47
1,74
2,23
2,97
+7 °C / +45 °C - Low temperature radiator
kW
1,30
1,50
1,87
2,53
-7 °C / +45 °C - Low temperature radiator
kW
1,86
2,04
2,47
3,70
Coefficient of performance (COP)
(+7 °C / + 35 °C)
4,52
4,27
4,08
4,02
Electrical characteristics
Supply voltage (50 HZ)
V
230
Maximum current for appliance
A
12,5
12,5
17,5
18,5
Nominal current
A
6,3
6,3
8,1
10,9
Maximum current of the electrical back-ups
A
26,1
Power of the electrical back-ups
kW
adjustable 3 or 6 kW
Real power absorbed by the fan
W
49
49
49
100
Real power absorbed by the circulation pump
W
up to 70
Maximum power absorption by the outdoor unit
W
2530
2875
4025
4255
Hydraulic circuit
Maximum operating pressure
MPa (bar)
0,3 (3)
Hydraulic system flow rate (mini/maxi) 4°C<Δt<8°C (nominal conditions)
l/h
490 / 970
650 / 1300
810 / 1620
1080 / 2160
Various
Weight of outdoor unit
kg
41
41
42
60
Sound power level according to EN 12102
1
(hydraulic unit)
dB
46
Sound power level according to EN 12102
1
(outdoor unit)
dB
65
65
65
68
Weight of hydraulic unit (empty / full of water)
kg
42 / 58
Water capacity of the hydraulic unit
l
16
Heating system operating limits
Hydraulic unit operation range
°C
0 / +45
Outdoor temperature mini/maxi
°C
-20 / +35
Initial max. heating water temperature Floor heating system
°C
45
Initial max. heating water temperature Low temperature radiator
°C
55
Flow min. heating water temperature
°C
8
Refrigeration circuit
Diameter of gas pipes
inches
1/2
1/2
5/8
5/8
Diameter of liquid pipes
inches
1/4
1/4
1/4
3/8
Factory charge of refrigerant R410A
2
g
1100
1100
1400
1800
Maximum operating pressure
MPa (bar)
4,15 (41,5)
Minimum length of pipes
m
5
Maximum length of pipes
3
m
15
Maximum length of pipes
4
m
30
Maximum level difference
m
20
1
The sound power level is a laboratory measure of the emitted sound power
but contrary to the noise level, it doesn't correspond to the measure of the felt.
2
Refrigerant R410A (as per the standard EN 378.1).
3
Factory charge of refrigerant R410A.
4
Taking into account the possible additional load of refrigeration fluid R410A
(see
Содержание WOYA060LFCA
Страница 23: ... Installation and operation manual 1764 EN 23 Air to Water Heat Pump split system ...
Страница 29: ... Installation and operation manual 1764 EN 29 Air to Water Heat Pump split system ...
Страница 33: ...Installation and operation manual 1764 EN 33 Air to Water Heat Pump split system ...
Страница 35: ... Installation and operation manual 1764 EN 35 Air to Water Heat Pump split system ...
Страница 71: ...Installation and operation manual 1764 EN 71 Air to Water Heat Pump split system ...
Страница 73: ... Installation and operation manual 1764 EN 73 Air to Water Heat Pump split system ...
Страница 79: ... Installation and operation manual 1764 EN 79 Air to Water Heat Pump split system ...
Страница 86: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 86 ...
Страница 87: ...Installation and operation manual 1764 EN 87 Air to Water Heat Pump split system ...
Страница 88: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 88 ...
Страница 89: ...Installation and operation manual 1764 EN 89 Air to Water Heat Pump split system ...
Страница 90: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 90 ...
Страница 91: ... Installation and operation manual 1764 EN 91 Air to Water Heat Pump split system ...