background image

En-10

Setting

SW No.

SW setting

Function

Mode

SW104-1

ON

Mode1

OFF output

SW104-2

OFF

Disabled

Polarity

SW104-3

ON

OFF

ON SCENE1

ON

OFF SCENE2

SW104-4

OFF

ON 

 OFF SCENE3

OFF 

 ON SCENE4

CH2 setting

EXIN

0

Operation stop

OFF TIMER

SW103

2

Stop after 3 hours

SCENE

Setting

SW No.

SW setting

Function

SCENE1

Operation stop

SW107-1/2

OFF/ON

Operation

Fan speed

SW107-3/4

OFF/OFF

No change

Operation mode SW108-1/2

ON/ON

No change 2

All operation

SW108-3/4

OFF/OFF

No change

Set temperature 

1

SW111-

1/2/3/4

ON/ON/

OFF/ON

26°C (80°F)

Set temperature 

2

SW112-

1/2/3/4

ON/OFF/

ON/OFF

20°C (68°F)

SCENE2

Operation stop

SW105-1/2

OFF/OFF

No change

Fan speed

SW105-3/4

OFF/OFF

No change

Operation mode SW106-1/2

ON/ON

No change 2

All operation

SW106-3/4

OFF/OFF

No change

Set temperature 

1

SW109-

1/2/3/4

ON/ON/

ON/ON

30°C (88°F)

Set temperature 

2

SW110-

1/2/3/4

ON/OFF/

OFF/OFF

16°C (60°F)

12. TURNING ON THE POWER

(1)  Check this product wiring and switch settings on the circuit board.
(2)  Check the wiring and switch settings for the VRF system or multi 

system or single model. For the wiring and switch settings method, 
refer to the installation instruction sheet of each unit.

(3)  Turn on the power for the VRF system or multi system or single 

model.

(4)  Power will be supplied from the system to the convertor.

 

This product will be initialized and the power turned on. 
LED1 (green) and LED2 (orange) will 

fl

 ash.

 

After initial setting is completed, operation will be restarted auto-
matically. 
LED1 (green) lights.

 

This product does not operate during initialization.

 

* An error code will appear on LED in the event of a malfunction.

13. LED DISPLAY

13. 1. 

Normal code

Normal indications

Normal contents

LED1 

(green)

LED2  

(orange)

LED3  

(red)

During initialization (during initializa-
tion sequence)

Normally operating

Display mode 

 :  On

 

 :  Off

 

 : Flashing

13. 2. 

Error code

When error occurs in the remote controller connected to the Network 
convertor, please refer to the installation manual of the remote controller 
and indoor unit.

Error indications

Error contents

LED1 

(green)

LED2  

(orange)

LED3  

(red)

 (1)

 (2)

Remote controller communication 
error

 (1)

 (5)

Scan error

 (2)

 (6)

Indoor unit address setting error

 (11)

 (2)

Peripheral unit transmission PCB er-
ror

Display mode 

 : 0.5s ON / 0.5s OFF

 

 : 0.1s ON / 0.1s OFF

 

( ) : Number of flashing

• Switch location map

9374707157-02_IM.indb   10

9374707157-02_IM.indb   10

12/2/2016   5:22:46 PM

12/2/2016   5:22:46 PM

Содержание UTY-TERX

Страница 1: ...ONTROLLER For authorized service personnel only 安装说明书 安装说明书 外部开关控制器 仅针对授权的专业维修人员 English 中 文 中 文 PART NO 9374707157 02 Original instructions UTY TERX 9374707157 02_IM indb i 9374707157 02_IM indb i 12 2 2016 5 22 43 PM 12 2 2016 5 22 43 PM ...

Страница 2: ...ntive measures so that they cannot reach the unit CAUTION This mark indicates procedures which if improp erly performed might possibly result in personal harm to the user or damage to property Pay abundant care when transporting this unit because it is a precision device Improper transportation will cause trouble Do not touch the switches with sharp objects Doing so will cause injury trouble or el...

Страница 3: ...er supply cable connection cable and remote controller cable 1 m 40 in away from television and radio to avoid distorted images and noise Otherwise a malfunction could result Perform wiring so that water does not enter this unit along the external wiring Always install a trap to the wiring or take other countermeasures Otherwise it will cause trouble or electric shock or fire Confirm the name of e...

Страница 4: ...controller Y1 Y2 Y3 External input EXIN1 EXIN2 0 5 to 0 6 N m 4 4 to 5 3 lbf in 5 to 6 kgf cm 5 1 Wiring method Indoor unit VRF single multi Wired remote controller Wired remote controller cable This product External input cable Card key Window switch Connectable types of indoor unit and remote controller The wired remote controller shown in the table below can be connected The indoor unit that ca...

Страница 5: ...e DIP switches Before opening the cover of this unit completely discharge static electric ity charged on your body Otherwise failure or malfunction could result Do not touch the circuit board and circuit board parts directly with your hands Otherwise injury or electric shock could result Tightening the mounting screws too tight will damage the body of this unit 6 1 Connecting the cables 1 Turn off...

Страница 6: ...connection method is differ ent depending on each model Modify the remote controller cable as per below description and connect it For the details refer to the installation manual of the indoor unit to be used 1 When connecting to the connector Case 1 For non polar 2 wire Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of...

Страница 7: ...le is 50m 164 ft 9 CIRCUIT BOARD SETTING The circuit board has a rotary switch DIP switch and LED as shown below 1 About connections 1 1 2WIRE 3WIRE settings SET3 Remote controller 2WIRE 3WIRE switching SW Default 2WIRE Set matched with the connection method of the remote controller cable to be connected 1 2 Master settings SET 2 1 When setting the SET3 to 3WIRE DIP SW OFF ON SET 2 1 Master Slave ...

Страница 8: ... Mode 1 SW104 1 1 Polarity setting SW104 3 4 DIP SW Setting OFF ON SW104 3 No function Fixed to OFF SW104 4 CH2 external switch detection condition ON OFF is SCENE3 OFF ON is SCENE4 OFF ON is SCENE3 ON OFF is SCENE4 Factory setting 2 Rotary switch setting EXIN Rotary switch setting value Setting SCENE3 SCENE4 0 Operation stop Operation Stop 1 Remote controller pro hibition all operation All operat...

Страница 9: ... If operation mode is set to No change 2 the operation mode is not changed If this scene is run 1 If operation mode is COOL or DRY the set temperature will be changed to set temperature 1 2 If operation mode is HEAT the set temperature will be changed to set temperature 2 3 If operation mode is AUTO or fan the set temperature is not changed Remote controller prohibition all operation SW108 3 4 SCE...

Страница 10: ...speed SW105 3 4 ON OFF Hi Operation mode SW106 1 2 ON OFF COOL All operation SW106 3 4 OFF OFF No change Set tempera ture 1 SW109 1 2 3 4 OFF OFF OFF ON 23 C 74 F Set tempera ture 2 SW110 1 2 3 4 OFF OFF OFF OFF No change 2 Example setting 2 When a window is opened operation stop remote controller opera tion prohibited return to original state when the window is closed For specifications where con...

Страница 11: ...h settings method refer to the installation instruction sheet of each unit 3 Turn on the power for the VRF system or multi system or single model 4 Power will be supplied from the system to the convertor This product will be initialized and the power turned on LED1 green and LED2 orange will flash After initial setting is completed operation will be restarted auto matically LED1 green lights This ...

Отзывы: