background image

En-7

4

Set the “Day”, “Month”, and “Year”.

Switch the setting item with [Cursor button (Left/Right)], and adjust 

with [Cursor button (Up/Down)].
When [Cancel button] is pressed, it returns to the “Change display 

format” screen.

Year

Day

Monday

08

2012

Month

Date

20

OK: 

Cancel:

When [Enter button] is pressed, the “Time” screen is displayed.

5

Set the “hour” and “min”. 

Switch the setting item by [Cursor button (Left/Right)], and adjust with 

[Cursor button (Up/Down)].
“Min” can be set quickly if the button is pressed continuously.

When [Cancel button] is pressed, it returns to the “Date” screen.

min

00

AM

hour

Time

OK:

Cancel:   

10:

When [Enter button] is pressed, the “Confirmation” screen is displayed.

6

When setting is completed, select “Yes” with [Cursor button (Left/

Right)], and press [Enter button].

When correcting a setting, set it again as it returns to the “Language” 

screen when “No” is selected and press [Enter button].

Initial setting will be ended. OK?

No

Yes

9. SERVICE SCREEN SETTING

When [Menu button] is pressed twice while “Monitor” screen is displayed, it 

switches to the “Submenu” screen. 

Press the [Screen switch button (Left)] and [Screen switch button (Right)] 

simultaneously for 5 seconds to switch to “Service” screen.

Back:

Setting:

Date and time

Submenu  

[

1/2

]

Monitor

Screen

Filter sign

R.C. sensor control

Room temp. display

Off

Off

Mo 10:00AM

Back:                              Setting: 

Service                                            

Mo 10:00AM

Function setting

Error history

I.U.address verification

Version

Test   run

(R.C. Sensor control : Remote Controller sensor control)

(I.U.address verification : Indoor Unit address verification)

Service screen

Function name

Setting

Primary unit

Secondary unit

Test run
Function setting
Error history

I.U.address verification

Version

9.1. Test run

If the unit is operating, turn it off.

• 

Test run stops in 60 minutes.

• 

 

When the [On/Off button] is pressed during 

the test run, the test run will be canceled.
After completing the test run, wait enough until starting the operation.

• 

1

When [Menu button] is pressed twice while “Monitor” screen is dis-

played, it switches to the “Submenu” screen. 

If [Menu button] is pressed while the “Submenu” screen is displayed, 

the display returns to the “Monitor” screen.

Back:

Setting:

Date and time

Submenu  

[

1/2

]

Monitor

Screen

Filter sign

R.C. sensor control

Room temp. display

Off

Off

Mo 10:00AM

2

Press the [Screen switch button (Left)] and [Screen switch button 

(Right)] simultaneously for 5 seconds to switch to “Service” screen.

Back:                              Setting: 

Service                                            

Mo 10:00AM

Function setting

Error history

I.U.address verification

Version

Test   run

When you select [Test run] with the [Cursor button (Up/Down)] and press the 

[Enter button], following confirmation screen is displayed.

To start the test run, select “Yes” with the [Cursor button (Left/Right)], and 

press the [Enter button].

In Set temp, test run is displayed.

The test run will be performed. OK?

No

Yes

Mode

Menu

Cool

Monitor

Set  temp.

Fan

High

   Mo 10:00AM

Test

run

9.2. Function setting

This procedure changes the function settings used to control the indoor unit 

according to the installation conditions. Incorrect settings can cause the 

indoor unit to malfunction. This procedure should be performed by author-

ized installation or service personnel only.

Perform the “FUNCTION SETTING” according to the installation conditions 

using the remote controller. (Refer to the indoor unit installation manual for 

details on the function numbers and setting values.)
Perform the setting during the operation is stopped.

1

When [Menu button] is pressed twice while “Monitor” screen is dis-

played, it switches to the “Submenu” screen. 

If [Menu button] is pressed while the “Submenu” screen is displayed, 

the display returns to the “Monitor” screen.

Back:

Setting:

Date and time

Submenu  

[

1/2

]

Monitor

Screen

Filter sign

R.C. sensor control

Room temp. display

Off

Off

Mo 10:00AM

2

Press the [Screen switch button (Left)] and [Screen switch button 

(Right)] simultaneously for 5 seconds to switch to “Service” screen.

Back:                              Setting: 

Service                                            

Mo 10:00AM

Function setting

Error history

I.U.address verification

Version

Test   run

9380222057_IM.indb   7

28/8/2555   10:33:45

Содержание UTY-RVNUM

Страница 1: ... RVNUM PART No 9380222057 INSTALLATION MANUAL For authorized service personnel only MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Sólo para personal de mantenimiento autorizado English Français Español ...

Страница 2: ...y affect the equipment such as sulfuric gas chlorine gas acid or alkali It will cause the cop per pipes and brazed joints to corrode which can cause refrigerant leakage Area containing equipment that generates electromagnetic interference It will cause the control system to malfunction preventing the unit from operating normally Area that can cause combustible gas to leak contains suspended carbon...

Страница 3: ...Remote controller cable 0 33 mm2 22AWG Polar 3 core Use sheathed PVC cable We recommend that you purchase our service parts for the remote control ler cable Contact service personnel to purchase this 4 SELECTING AN INSTALLATION LOCATION 4 1 Dimensions 4 23 32 120 Unit in mm 4 23 32 120 1 25 32 45 3 2 16 32 63 5 19 32 15 3 3 9 32 83 5 6 32 4 5 6 32 4 5 16 32 12 5 7 32 21 3 1 6 32 30 11 32 9 1 10 32...

Страница 4: ...iring will damage the electric parts and cause smoke and fire When installing the connection cable near a source of electromagnetic waves use shielded cable Otherwise a breakdown or malfunction could result 5 2 Connection of remote controller cable CAUTION When connecting the remote controller cable to the wall mounted type and the floor type indoor unit do not connect it to the outdoor unit or th...

Страница 5: ...roller 1 6 32 30 or more 8 21 32 220 or more Unit in mm 1 6 32 30 or more 1 6 32 30 or more Please secure enough space where a flat screwdriver to take off a case can be inserted 5 3 2 Processing of the remote controller cable Unit in mm 2 5 32 55 1 12 V Red 2 Signal White 3 COM Black 1 25 32 45 1 6 32 30 10 32 8 10 32 8 10 32 8 5 3 3 Remove the front case Insert the flat screwdriver and remove th...

Страница 6: ...N the settings information will be lost if there is a power failure Registered information such as that for the internal unit is not erased even if the DIP switch is turned off DIP switch ON OFF 1 2 Front case back side No Switch state Detail OFF ON DIP switch 1 Invalidity Validity Memory backup setting Set to ON to use batteries for the memory backup If batteries are not used the settings informa...

Страница 7: ...ntrollers Primary unit Secondary unit DIP Switch No 2 DIP Switch No 2 1 Normal OFF 2 Dual OFF ON 7 TURNING ON THE POWER CAUTION Recheck the wiring Incorrect wiring will cause trouble Check the remote controller wiring and DIP switch settings 1 Install the front case 2 in 5 INSTALLING THE REMOTE CONTROLLER Check the indoor and outdoor unit wiring and circuit board switch set 3 tings and then turn o...

Страница 8: ...ng the operation 1 When Menu button is pressed twice while Monitor screen is dis played it switches to the Submenu screen If Menu button is pressed while the Submenu screen is displayed the display returns to the Monitor screen Back Setting Date and time Submenu 1 2 Monitor Screen Filter sign R C sensor control Room temp display Off Off Mo 10 00AM 2 Press the Screen switch button Left and Screen s...

Страница 9: ...ter button Back Setting Service Mo 10 00AM Function setting Error history I U address verification Version Test run Version Mo 10 00AM E031VXXPXXLXX Back I U address Function set 10 SETTING THE ROOM TEMPERATURE DETECTION LOCATION The detection location of the room temperature can be selected from the following 2 examples Choose the detection location that is best for the installation location Refe...

Страница 10: ...n Initial is selected in Submenu screen Initial screen is displayed Enter current password with the Cursor button and press the Enter button Initial Management Key lock select Child lock Submenu 2 2 Mo 10 00AM Back Setting Monitor 3 Select Password setting Management in the Initial screen and press the Enter button Mo 10 00AM Back Setting Initial Language English Temp unit Password setting Managem...

Страница 11: ...k in Management select screen are listed in Man agement function screen Mo 10 00AM Back Setting Edit Management function Economy Disable Disable Off Set temp range On timer 5 In Management function screen you can change the detailed setting on each function For how change the setting refer to each function setting in 3 FUNCTION SETTING in the operating manual Mo 10 00AM Back Setting Edit Managemen...

Отзывы: