background image

PART NO. 9373328148-02

INSTALLATION MANUAL

AIR CONDITIONER
REMOTE CONTROLLER
(WIRED TYPE)
UTY-RNNUM

Contents

1. SAFETY 

PRECAUTIONS 

............................................. 2

2. ACCESSORIES 

............................................................ 2

3. ELECTRICAL 

REQUIREMENT 

..................................... 2

4.  SELECTING AN INSTALLATION LOCATION ............... 3

4.1. Dimensions ............................................................ 3
4.2. Name of parts ......................................................... 3

5.  INSTALLING THE REMOTE CONTROLLER ............... 4

5.1.  Installation .................................................................4
5.2. Setting the DIP switch ............................................ 4
5.3. Connection of remote controller cable ................... 5

6. INSTALLATION 

METHODS 

.......................................... 5

6.1. Group control ......................................................... 5
6.2.  Dual remote control ............................................... 6

7.  TURNING ON THE POWER ......................................... 6
8.  SETTING THE ROOM TEMPERATURE DETECTION 

LOCATION .......................................................................6

9. FUNCTION 

SETTING 

................................................... 7

10. TEST OPERATION ....................................................... 9
11. ERROR CODES ........................................................... 9

For authorized service personnel only.

English

Français

Español

9373328148-02_IM_EN_FR_SP.indb   1

9373328148-02_IM_EN_FR_SP.indb   1

9/14/2010   1:14:03 PM

9/14/2010   1:14:03 PM

Содержание UTY-RNNUM

Страница 1: ...ons 3 4 2 Name of parts 3 5 INSTALLING THE REMOTE CONTROLLER 4 5 1 Installation 4 5 2 Setting the DIP switch 4 5 3 Connection of remote controller cable 5 6 INSTALLATION METHODS 5 6 1 Group control 5 6 2 Dual remote control 6 7 TURNING ON THE POWER 6 8 SETTING THE ROOM TEMPERATURE DETECTION LOCATION 6 9 FUNCTION SETTING 7 10 TEST OPERATION 9 11 ERROR CODES 9 For authorized service personnel only E...

Страница 2: ... with your hands Do not wire the remote controller cable together with or parallel to the connection cables and power supply cables of the indoor unit and outdoor unit It may cause erroneous operation When installing cable near a source of electromagnetic waves use shielded wire Do not set the DIP switches either on the air conditioner or the remote controller in any way other than indicated in th...

Страница 3: ...ection and swing Button C Economy Thermo Sen sor Button D Maintenance Filter Reset Button E Operation Lamp F Day Display G Operation Lock Display H Temperature Display I Fan Speed Display J Timer Mode Display K Operation Mode Display L Timer and Clock Display M Filter Display N Economy Display O Thermo Sensor Display P Vertical Swing Display Q Horizontal Swing Display R Defrost Display 4 SELECTING...

Страница 4: ...NSTALLING THE REMOTE CONTROLLER 5 1 Installation 5 1 1 Installing the remote controller Open the operation panel on the front of the remote controller remove the 2 screws indicated in the following figure and then remove the front case of the remote controller When installing the remote controller remove the connector from the front case The wires may break if the connector is not removed and the ...

Страница 5: ...1 2 Connect the remote controller cable and connecting cable as shown in Fig 2 3 Be sure to insulate the connection between the cables Connecting cable Connector Fig 1 Fig 2 White Red White Red Black Black Insulated connection Remote controller cable Remote controller cable 20 mm 13 16 in 5 3 2 When connecting to the exclusive terminal block Connect the end of remote controller cable directly to t...

Страница 6: ...ting factory setting The room temperature is detected by the indoor unit temperature sensor 1 When the button is pressed the lock display flashes because the function is locked at the factory A Indoor unit B Indoor unit remote controller setting room temperature sensor selection The temperature sensor of the indoor unit or the remote controller can be used to detect the room temperature When use t...

Страница 7: ...oor unit SU MO TU WE TH FR SA 6 Repeat steps 2 to 5 to perform additional settings Press the button button and simultaneously again for more than 5 seconds to cancel the function setting mode In addition the function setting mode will be automatically canceled after 1 minute if no operation is performed 7 After completing the FUNCTION SETTING be sure to turn off the power and turn it on again Func...

Страница 8: ...tandard 31 00 Lower control 01 Slightly warmer control 02 Warmer control 03 7 Auto restart Enable or disable automatic system restart after a power outage Factory setting Setting Description Function Number Setting Value Yes 40 00 No 01 Auto restart is an emergency function such as for power fail ure etc Do not start and stop the indoor unit by this function in nor mal operation Be sure to operate...

Страница 9: ...lamp will light up and 1 will be displayed on the set temperature display Perform the test operation for 60 minutes Pressing the START STOP button will stop the test operation Test operation display 11 ERROR CODES If you use a wired type remote control error codes will appear on the remote control display If you use a wireless remote control the lamp on the IR receiver unit will output error codes...

Страница 10: ...oor unit Active filter error Outdoor unit 6 5 IPM error Outdoor unit 6 10 Display panel error Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit 9 4 Trip detection Outdoor unit Outdoor unit Outdoor unit 9 9 10 1 4 way valve error Outdoor unit Discharge temperature 1 error Refriger ant system Display mode 0 ...

Отзывы: