TEMPERATURE SET BACK TIMER

Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only.

The timer function is not available depending on the model.

To set the temperature SET BACK timer

3

● 

Day setting

● 

Operating time setting

Follow steps 

3

 and 

4

 in “To set the WEEKLY timer” (p. 5). The DELETE button is also used as described in the procedures

for the weekly timer.

4

NOTES

(1) The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.
(2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.
(3) The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
(4) During the COOL/DRY mode, the air conditioner will operate at a minimum of 18 °C even if the SET BACK temperature

is set to 17 °C or lower.

(5) The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET

BACK confirmation display.)

(6) Room temperatures as low as 10, 12, and 14 °C cannot be set depending on the model.

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

DAY OFF

DAY

1

3

SET

2

SET

4

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

ex. When setting all days together

● 

Temperature setting

Press the SET TEMPERATURE buttons to
set the temperature (from 10 °C to 30 °C).

ex. Operating time 15:00–22:00

5

Repeat steps 

3

 and 

4

.

Press the SET button for 2
seconds or more to com-
plete the temperature SET
BACK timer settings.

SET

SET BACK

temperature

Normal

temperature

To start/cancel the temperature SET BACK timer operation

● 

To start

SET BACK

Press the SET BACK button. The SET BACK confirmation
display appears for 5 seconds, and then the timer starts au-
tomatically.

ex. Display during SET BACK timer operation
(The operating time will not be displayed.)

● 

To cancel

Press the SET BACK button, and then press the DELETE
button while the SET BACK confirmation display is dis-
played. Even if the SET BACK button is pressed again, the
SET BACK timer will be cancelled.

SET BACK

1

DELETE

2

SU MO TU WE TH FR SA

Press the SET BACK button to change to the SET BACK confirmation display.
The SET BACK operating time and the set temperature will be displayed.

2

Press the SET button for 2
seconds or more.

1

SET BACK

SET

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

If there is no existing
SET BACK tempera-
ture setting, “- -” will
be displayed for the
temperature.

24

°

C

24

°

C

28

°

C

ON

OFF

Содержание UTH-3TA16

Страница 1: ...UAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Remote Controller UTH 3TA16 REMOTE CONTROLLER WIRED TYPE English Deutsch Français Español Italiano EλληvIkά Русский Português SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 ...

Страница 2: ...perly performed are most likely to result in the death of or serious injury to the user or service personnel Do not attempt to install this controller by yourself This controller contains no user serviceable parts Al ways consult authorized service personnel for repairs When moving consult authorized service personnel for disconnection and installation of the controller Display panel If a problem ...

Страница 3: ...can be operated Button cannot be operated If a button indicated with is pressed the operation lock display I on page 1 flashes but the air conditioner will not respond 1 If the wired remote controller is connected to the indoor unit a wireless remote controller cannot be used 2 Before connecting the remote controller the remote controller cord must be modified 3 The fan speed cannot be changed for...

Страница 4: ...etting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 10 12 14 or 16 to 30 C Lower Raise Operation lamp Air conditioner ON Lit brightly Air conditioner OFF Not lit Press the START STOP button Press the MASTER CONTROL button to set the operation mode If DRY is selected the fan speed will be set to AUTO Press the SET TEMPERATURE buttons to set the room temperature Press the FAN CONTROL button to set...

Страница 5: ...ly again During cooling operation do not set the vertical airflow direction louver in the downward position for an ex tended period Water vapor may condense near the out let port and drops of water may drip from the air condi tioner 2 The range of swing is relative to the currently set airflow direction The SWING operation may stop temporarily when the air conditioner s fan is not operating or whe...

Страница 6: ...s the TIMER MODE button to select the ON TIMER or OFF TIMER 2 Press the DELETE button to cancel the timer mode The timer mode can also be canceled by changing the timer mode using the TIMER MODE button 1 CLOCK ADJUST No display SU MO TU WE TH FR SA Press the SET TIME buttons to set the time After the time is set the timer will start automatically The amount of time until the OFF timer operates tha...

Страница 7: ... time setting Set the OFF time in the same way If necessary set the second weekly timer settings in the same way When the operating time is set the mark appears 6 Press the SET button for 2 seconds or more to com plete the weekly timer set tings SET To delete the operating time DELETE If the DELETE button is pressed during steps 3 or 4 the operating time for the selected day will be deleted If all...

Страница 8: ...F NOTES 1 PRECAUTIONS DURING WEEKLY TIMER SETUP Setup is not possible in the following cases so amend the time Be sure to set the ON time first then the OFF time If either the ON time or the OFF time is not set cor rectly the timer will not operate properly The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings The WEEKLY 1 and WEEKLY 2 time spans cannot overlap 2 The earliest OFF ...

Страница 9: ... SA 3 6 9 12 15 18 21 DAY OFF DAY 1 3 SET 2 SET 4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the SET TEMPERATURE buttons to set the temperature from 10 C to 30 C ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the SET button for 2 seconds or more to com plete the temperature SET BACK timer settings SET SET BACK temperature Normal t...

Страница 10: ...ation mode the mode will be shut off The temperature set on the remote controller will not change if the energy save mode is used Weekly timer Set different operating times for each day of the week Set one or two operating spans one or two ON times and one or two OFF times per day Set time to a resolution of 30 minutes OFF time can be carried over to the subsequent day Use the DAY OFF setting to c...

Страница 11: ... the main power switch set to the OFF position Is the timer operating CHECK ONCE MORE If the problem persists after performing these checks or if you notice burning smells immediately stop operation turn off the electrical breaker and consult authorized service personnel SPECIFICATIONS REMOTE CONTROLLER WIRED TYPE MODEL POWER DIMENSIONS WEIGHT HEIGHT mm WIDTH mm DEPTH mm WEIGHT g UTH 3TA16 DC 12 V...

Отзывы: