Supplement for Embedded MegaRAID SATA User
’
s Guide
Description
Not detecting hard disks and unmatched insert locations
Message
The displayed message is different according to the situation.
[Message 1]
WARNING!
BIOS detected configured disks w. some drive(s) missing, pls power off the
system, remove the drive from port:
XX
and reinsert it in another slot.
Press any key to continue.
(*Press any key, and the following message appears.)
If you proceed, you'll lose this configuration.
Press any key to continue.
[Message 2]
Missing Drive reassigned to Port
XX
Or,
Missing Drive cannot be relocated
PD(s) reassigned to different slot(s) because originally configured slot(s) have
different PD(s).
If you believe this is not a desired behavior, pls. power off the system and return the
PD(s) to their original slots to restore the previous configuration.
Otherwise, press any key to accept the resolved configuration
Press any key to continue.
Meaning
The hard disk connecting to the port XX was connected to the other port at the last
startup. The hard disk connecting to the port XX last time is not found.
In case of
[message 1]
, The configuration information will be cleared by pressing
any key to continue.
In case
of
[message 2],
The configuration information will be reconstructed by
pressing any key to continue, but consistency of configuration information is not
supported.
Action
Contact an office listed in the
“
Contact Information
”
of
“
Start Guide
”
.
Configuration information of the logical drives is not changed when turning off or
restarting the server while this message is displayed waiting for key-in.
12 / 13