background image

Supplement for Embedded MegaRAID SATA User

s Guide 

CA97232-0014-01EN

 
 
 
 
 
 
 
 
 
 
 
 

Supplement for   

Embedded MegaRAID SATA 

User’s Guide 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1 / 13 

Содержание Supplement for Embedded MegaRAID SATA

Страница 1: ...Supplement for Embedded MegaRAID SATA User s Guide CA97232 0014 01EN Supplement for Embedded MegaRAID SATA User s Guide 1 13 ...

Страница 2: ...____ 6 4 1 2 Requirements for ServerView RAID page 57 6 4 1 3 Access Privileges to ServerView RAID page 58 7 4 2 1 Operation via Network page 60 7 4 2 5 Monitoring Event Log page 63 7 4 3 1 How to Install ServerView RAID page 65 7 4 3 2 How to Uninstall ServerView RAID page 66 8 4 4 1 Installing HDD Check Scheduler page 68 8 4 4 2 Modifying HDD Check Start Time page 69 8 4 4 4 Uninstallation of HD...

Страница 3: ...ice Refer to the website http www fujitsu com global contact computing PRMRGY_index html Trademarks Microsoft Windows and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries Linux is a trademark or registered trademark of Linus Torvalds in the USA and other countries Red Hat and Red Hat based trademarks and logos are trademarks or register...

Страница 4: ...ws Note 2 When it is not particularly marked in this document it is included in Windows Server 2008 2 1 SATA Setup Utility page 24 Version of expansion ROM BIOS is displayed as BIOS Version when using expansion ROM BIOS A 06 05071459R 3 1 Updating Device Drives page 52 z z 3 3 1 1 1 1 C Cr re ea at ti in ng g D Dr ri iv ve er r D Di is sk k The table Driver disk on page 52 is changed as follows OS...

Страница 5: ...te Driver The Update Driver Software window appears 7 Click Browse my computer for driver software 8 Click Let me pick from a list of device drivers on my computer 9 Click Have Disk 10 Click Browse button and select the file as follows For Windows Server 2008 CD DVD Drive Drivers MegaSR W2K8 MegaSR INF For Windows Server 2008 x64 CD DVD Drive Drivers MegaSR W2K8x64 MegaSR INF 11 Click OK Confirm t...

Страница 6: ...oller installed Web browser note Internet Explorer 6 or later Mozilla Firefox 1 0 4 or later SeaMonkey 1 0 3 or later Java note Java 2 Runtime Environment Standard Edition V1 5 0_06 or later note When in one of the environment listed bellow those software are not necessary to be installed in the server that ServerView RAID is installed However the environment that those software can be operated at...

Страница 7: ...ettings and status of the RAID subsystems such as the array controllers hard disks and logical drives However you cannot rebuild hard disks or modify the parameters for ServerView RAID raid usr group should be created upon necessity 4 2 1 Operation via Network page 60 The following information is added to the POINT in 4 2 1 Operation via Network on page 60 When in Windows Server 2008 firewall is e...

Страница 8: ... command from the command prompt wmic product where name ServerView RAID Manager call uninstall 3 Restart the system 4 4 1 Installing HDD Check Scheduler page 68 When in ServerCore installation with Windows Server 2008 The instruction in 4 1 1 Installing HDD Check Scheduler on page 68 is partially changed as follows Step 3 Click Start button Run Type the following file name and click OK As for the...

Страница 9: ...003 Refer to the Procedure of Windows Server 2003 for implementation 4 5 1 Preparation and Precautions for using ServerView RAID Manager page 72 Regarding the article in General precautions on page 72 further information is added as follows Web browser cannot be operated when ServerCore is installed with Windows Server 2008 In this situation prepare the server or client PC for Windows to implement...

Страница 10: ...ge 87 When using ServerView RAID V3 0 14 00 or later following setting is displayed under File logging Option Setting Description Text format additionally Disabled Default Additional event log of text format is recorded The table of the POINT on page 89 is partially modified as follows Table At the destination of event log files For Windows Server 2003 or Windows Server 2008 C Program Files Fujits...

Страница 11: ... Handling on page 108 is partially modified as follows Description Detecting a logical drive being rebuilt Message PORT x is Rebuilding State WARNING Array s in Degraded Mode XX Virtual drive s Configured Array Mode Stripe Size No Of Stripes DriveSize Status 00 RAID 1 64KB 02 XXXXXXMB Degraded Meaning The hard disc x connected to the port x is being rebuilt and the logical drive is critical degrad...

Страница 12: ...his is not a desired behavior pls power off the system and return the PD s to their original slots to restore the previous configuration Otherwise press any key to accept the resolved configuration Press any key to continue Meaning The hard disk connecting to the port XX was connected to the other port at the last startup The hard disk connecting to the port XX last time is not found In case of me...

Страница 13: ...08 Issued by FUJITSU LIMITED The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu 13 13 ...

Отзывы: