Fujitsu SPLIT TYPE AIR CONDITIONER Скачать руководство пользователя страница 13

12

11. TEST  RUNNING

• Perform test operation and check items 1 and 2

below.

• For the operation method, refer to the operating

manual.

• The outdoor unit may not run, depending on the

room temperature.  In this case, press the TEST
RUN button while the air conditioner is running. 

(With the transmit section of the remote control unit
facing the body, press the TEST RUN button with
the tip of a ball point pen.)

• To end test operation, press the remote control unit

START/STOP button. 

(When the air conditioner is run by pressing the
remote control unit TEST RUN button, the OPERA-
TION and TIMER Iamps will simultaneously flash
slowly.)

1. INDOOR  UNIT 

(1) Is operation of each button on the remote control

unit normal? 

(2)  Does each lamp light normally? 

(3) Do not air flow direction flap and louvers operate

normally?

(4)  Is the drain normal?

2. OUTDOOR  UNIT 

(1) Is there any abnormal noise and vibration during

operation?

(2)  Will noise, wind, or drain water from the unit disturb

the neighbors? 

(3)  Is there any gas leakage?

A

B

START

STOP

C

D

Fig. 43 

START/STOP button 

TEST RUN button

14. REMOTE  CONTROL  UNIT  lNSTALLATION

(1)  Check that the indoor unit correctly

receives the signal from the remote
control unit, then install the remote
control unit holder. 

(2)  Select the remote control unit hold-

er selection site by paying careful
attention to the following: 
Avoid places in direct sunlight. 
Select a place that will not be affected
by the heat from a stove, etc.

1. REMOTE  CONTORL  UNIT  HOLDER  INSTALLATION

Install the remote control unit holder to a wall or pillar
with the tapping screws.

Fig. 44

Tapping
screws

Insert

Slide up 

q

Mount the Holder. 

w

Set the Remote
Control Unit. 

e

To remove the
Remote Control
Unit (when use
at hand.)

For use as Wall Fixing Type 

Tapping
screws

Insert

Slide

q

Mount the Holder. 

w

Set the Remote
Control Unit. 

e

Attach the unit
to the holder as
shown.

Tapping
screws

12. FINISHING

(1)  Install the filter guide. 

(2)  Install the intake grilles. 

(3) Install side covers A and B (if the unit is installed in a

half-concealed orientation, only install side cover A). 

(4)  Install the air filters.

13. CUSTOMER  GUIDANCE

Explain the following to the customer in accordance
with the operating manual: 

(1)  Starting and stopping method, operation switching,

temperature adjustment, timer, air flow adjustment,
and other remote control unit operations. 

(2)  Air filter removal and cleaning. 

(3) Give the operating and installation manuals to the

customer.

For use as Handy Type

Содержание SPLIT TYPE AIR CONDITIONER

Страница 1: ...dges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Make sure the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to walls and floo...

Страница 2: ... polyethylene insulation for copper pipes as required to precise length of piping Wall thickness of the insulation should not be less than 5 16 8 mm 3 Use insulated copper wire for field wiring Outer diameter Thickness Small pipe 3 8 9 53 mm 1 32 0 8 mm Large pipe 3 4 19 05 mm 3 64 1 0 mm Table 1 Temperature Indoor Outdoor air intake air intake Cooling Maximum 90 F DB 73 F WB 115 F DB Minimum 65 F...

Страница 3: ...ge For indoor side pipe joint large pipe Coupler heat insulator small For indoor side pipe joint small pipe Nylon fastener For fixing the coupler heat insulator Special nut A large flange For installing indoor unit Special nut B small flange For installing indoor unit Installation template For positioning the indoor unit Auxiliary pipe assembly For connecting the piping Name and Shape Q ty Applica...

Страница 4: ... over the room 3 Do not install the unit where it will be exposed to direct sunlight 4 Install the unit where connection to the outdoor unit is easy 5 Install the unit where the drain pipe can be easily installed 6 Take servicing etc into consideration and leave the spaces shown in Fig 2 or 3 Also install the unit where the filter can be removed FOR HALF CONCEALED INSTALLATION 2 OUTDOOR UNIT 1 Lea...

Страница 5: ...ing position for Suspension bolt Ceiling Wall Template Drilling position for piping Fig 7 1 3 16 30 mm Suspension bolt pitch 63 1 600 mm 1 3 16 30 mm INDOOR UNIT TOP VIEW Dimensions Space Required for Installation For Half Concealed Installation Suspension bolt pitch should be as shown in Fig 7 Side cover B Right side 1 LOCATION OF CEILING SUSPENSION BOLTS 13 32 10 mm 6 3 32 155 mm 11 13 16 300 mm...

Страница 6: ... Installation When installing the indoor unit in a semi concealed orientation make sure to reinforce the insulation of the unit on all sides Drops of water may fall from the unit if it is not thoroughly insulated Anchor Bolt Strength 7 23 to 10 85 ft lbs 100 to 150 kgf Fig 11 Ceiling panel 13 32 to 19 32 10 to 15 mm Special nut A Included Special nut B Included M10 Nut Obtained locally 3 DRILLING ...

Страница 7: ...ks 4 CONNECTING THE PIPING 2 Remove outdoor unit cabinet A and cabinet D Fig 18 After removing the screws remove cabinet A by pushing it down Valve Cabinet A mounting direction Cabinet D Use the accessory screws at these points only Pipe Flare nut Small pipe Small width across flats 7 8 22 mm Large pipe Large width across flats 1 13 32 36 mm Table 3 1 OUTDOOR UNIT PROCESSING When the outdoor unit ...

Страница 8: ...0 to 350 kgf cm Large pipe 57 86 to 72 37 ft lbs 800 to 1 000 kgf cm Table 4 Flare nut tightening torque Outdoor unit side 1 Tighten the flare nut of the connection pipe at the outdoor unit valve connector The tightening method is the same as that as at the indoor side 2 Seal with the accessory putty so that water does not enter at the top of the pipe insulation installed to the connection pipe la...

Страница 9: ... from the closed state Table 5 4 Tighten the cap and charging valve of the two valves to the specified torque Table 6 5 VACUUMING AND ADDITIONAL CHARGE Table 6 Table 5 Cap Charging valve Tightening torque Large valve Small valve 10 85 to 14 47 ft lbs 150 to 200 kgf cm 5 07 to 6 51 ft lbs 70 to 90 kgf cm Open valve state Closed valve state If the handle is not fully open performance will drop and a...

Страница 10: ...hard polyvinyl chloride pipe VP25 outside diameter 1 1 2 38 mm During installation of the drain pipe be careful to avoid applying pressure to the drain port of the indoor unit When the pipe is long install supporters Fig 31 Do not perform air bleeding Always heat insulate 11 32 8 mm or over thick the indoor side of the drain pipe 1 Install insulation for the drain pipe See Figs 32 and 33 Cut the i...

Страница 11: ...rs Fig 38 1 Before starting work check that power is not being supplied to the outdoor unit 2 Match the terminal board numbers and connection cord colors with those of the outdoor unit Erroneous wiring may cause burning of the electric parts 3 Connect the connection cord firmly to the terminal board Imperfect installation may cause a fire 4 Always fasten the outside covering of the connection cord...

Страница 12: ...V A C 60Hz 2 Before turning on verify that the volt age is within the 187 to 253V range 3 Always use a special branch circuit and install a special receptacle to supply power to the air conditioner 4 Use a circuit breaker and receptacle matched to the capacity of the air conditioner 5 The circuit breaker is installed in the permanent wiring Always use a cir cuit that can trip all the poles of the ...

Страница 13: ...nit correctly receives the signal from the remote control unit then install the remote control unit holder 2 Select the remote control unit hold er selection site by paying careful attention to the following Avoid places in direct sunlight Select a place that will not be affected by the heat from a stove etc 1 REMOTE CONTORL UNIT HOLDER INSTALLATION Install the remote control unit holder to a wall...

Страница 14: ...isconnect Connect C Disconnect Disconnect D Table 8 1 When removing the cabinet iron plate be careful not to damage the indoor unit internal parts and sur rounding area outer case 2 When processing the cabinet iron plate be careful not to injure your self with burrs etc 2 Fasten the round flange optional to the fresh air intake as shown in Fig 47 If using half concealed installation attach to the ...

Страница 15: ...tor shortcircuited High pressure abnormal Outdoor discharge thermistor open circuited Outdoor discharge thermistor shortcircuited Discharge temperature abnormal Outdoor air temperature thermistor open circuited Outdoor air temperature thermistor shortcircuited Goes off Goes off Goes off Goes off Blinks Goes off Blinks Goes off Goes off Goes off Blinks Goes off Goes off Blinks Goes off Goes off Bli...

Страница 16: ...June 2000 353 Rt 46 W Fairfield NJ 07004 888 888 FGAI www fujitsugeneral com ...