background image

1. Understanding an Overview of the System 

Fan unit 

 

Redundant configuration 

 

Active replacement 

Hardware as whole 

 

Protection between CPUs by CRC (*1) 

 Dual power feed 

 Redundant configuration of pump 

 XSCF unit, console path, and path between domain and XSCF: 

Redundant configuration (in SPARC M12-2S 2BB configuration 

or larger) 

 Redundant configuration of LAN (by Oracle Solaris functions) 

 Redundant configuration of SAS controller 

 

Active addition and removal of SPARC M12-2S

 

Memory 

 

Memory mirror 

 Memory patrol 

 Dynamic degradation of memory 

(in units of pages) 

 Extended ECC

 

Built-in storage

 

 

Redundant configuration 

     (when RAID (*2) is configured) 

 

Active replacement 

     (when RAID (*2) is configured) 

PCIe card 

 Redundant configuration 

    (when in multipath configuration) 

 Active replacement 

*1  Stands for Cyclic Redundancy Check. 

The function mainly checks for errors in serial interface access such as reading or writing. 

*2  For an HDD, it is when a software RAID/hardware RAID is configured. For an SSD, it is when a software RAID is configured. 

Power supply unit 

 

Redundant configuration 

 

Active replacement 

XSCF 

 Log collection 

 Monitoring function 

 Active replacement 

     (XSCF unit in SPARC M12-2S 

     2BB configuration or larger) 

Legend: 

 

Technology minimizing  

  shutdowns due to failure 

 

Technology minimizing 

  maintenance shutdowns  

NEW 

NEW 

CPU 

 

 

Dynamic degradation of CPU 

      (in units of cache ways or CPU cores)  

 

 

RAS functions (ECC, parity, retry, etc.) 

SPARC M12-2/M12-2S 

- 14 - 

Содержание SPARC M12

Страница 1: ...Manual Code C120 0050 06EN March 2018 Fujitsu SPARC M12 Quick Guide ...

Страница 2: ...xternal Views of the Chassis This chapter shows external views of the chassis for each model 3 System Specifications This chapter describes the server and processor hardware specifications For details on firmware and software see Chapter 1 Understanding an Overview of the SPARC M12 M10 in the Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 System Operation and Administration Guide 4 Document Map Refer...

Страница 3: ...icating the manual code manual title and page and stating your points specifically through the following sites Global site http www fujitsu com global contact Japanese site http www fujitsu com jp products computing servers unix sparc contact Copyright 2017 2018 Fujitsu Limited All rights reserved Oracle and or its affiliates provided technical input and review on portions of this material Font Sy...

Страница 4: ... Solaris operating system The system can support system configurations that meet the purpose and scale of business by using CPU Activations and server connections through the building block BB method The database server processing of the core system has been accelerated with the aim of streamlining tasks and suppressing investment costs revolutionizing the businesses of customers ...

Страница 5: ...h flexible scalability SPARC M12 2S Providing excellent performance and high scalability this flagship server achieves high performance high reliability and world class scalability through building block connections Expansion Options PCI expansion unit The SPARC M12 offers a PCI expansion unit for I O slot expansion All the available server models support the PCI expansion unit which supports PCI ...

Страница 6: ...system such as one emphasizing isolation or resource availability by using various virtualization functions Reliability Starting with a new processor the SPARC64 XII with mainframe class reliability and through high reliability technologies such as data protection redundancy and dynamic degradation the SPARC M12 thoroughly pursues reliability Performance guarantee and continuous operation through ...

Страница 7: ...rstanding an Overview of the System The new processor the SPARC64 XII has substantially improved CPU core performance Business performance increases which streamlines tasks optimizing investment costs Designed with state of the art 20 nm technology the processor is capable of highly parallel processing of 8 threads per CPU core and up to 12 CPU cores 96 threads per CPU chip Secondary cache memory ...

Страница 8: ...s heat away when liquid changes into vapor VLLC can exhibit the maximum cooling capacity as a liquid cooled module that forcibly circulates refrigerant with a driving force rather than using surface tension natural convection or gravity to circulate refrigerant 1 Understanding an Overview of the System Pump Radiator Cooling plate In principle Implementation CPU Phase change of liquid Radiator Pump...

Страница 9: ...core CPU core CPU core CPU core Disaster occurs at operating site CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core Backup site Osaka CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core Operating site Tokyo CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core Backup site Osaka CPU core CPU core CPU core CPU core CPU core CPU core CPU cor...

Страница 10: ...nitial installation More CPUs More CPU cores 12 CPU cores CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core 4 CPU cores CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core 12 CPU cores CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CPU core CP...

Страница 11: ... expand a job etc You can also perform active maintenance on hardware 1 Understanding an Overview of the System Active maintenance of hardware CPU core CPU core Job A Memory I O CPU core CPU core Job B Job C CPU Activation assignment Memory I O CPU core CPU core SPARC M12 2S dynamically disconnected and planned hardware maintenance performed Disconnection Maintenance Addition of resources active a...

Страница 12: ...can have an independent OS run on domains by configuring virtual hardware environments domains in the firmware layer of a server Oracle Solaris Zone You can virtually divide the OS into zones and flexibly use the zones according to your business 1 Understanding an Overview of the System You can flexibly configure a system by selecting from the following three choices for a virtual environment acco...

Страница 13: ...odel Configuration Diagram Feature Strong failure isolation High flexibility Resource availability Oracle VM Server for SPARC All SPARC M12 models Job A Job B Job A Job A Job B Job B OS OS OS OS Firmware Firmware Hardware resources Hardware resources Hardware resources Firmware Hardware resources Firmware OS Job A Job B Firmware Hardware resources OS Zone Zone Kernel zone Kernel zone OS layer Shar...

Страница 14: ...n multipath configuration 1 For an HDD it is when a software RAID hardware RAID is configured For an SSD it is when a software RAID is configured XSCF Log collection Monitoring function Legend Technology minimizing shutdowns due to failure Technology minimizing maintenance shutdowns Memory Memory mirror Memory patrol Dynamic degradation of memory in units of pages Extended ECC Fan unit Redundant c...

Страница 15: ... RAID 2 is configured Active replacement when RAID 2 is configured PCIe card Redundant configuration when in multipath configuration Active replacement 1 Stands for Cyclic Redundancy Check The function mainly checks for errors in serial interface access such as reading or writing 2 For an HDD it is when a software RAID hardware RAID is configured For an SSD it is when a software RAID is configured...

Страница 16: ...r larger In a building block configuration you can replace the XSCF unit without stopping the system Redundant configuration of the SAS controller The SPARC M12 2 M12 2S further improves reliability by the duplication of disks via different SAS controllers with a software RAID 1 Understanding an Overview of the System The SPARC M12 supports active addition and removal of hardware and newly support...

Страница 17: ...oftware On Chip SWoC 1 The function is capable of high speed encryption without using a dedicated adapter for encryption processing so there is neither an additional cost nor performance degradation 1 Understanding an Overview of the System You can configure a highly reliable and secure system environment by using Oracle Solaris The SPARC64 XII processor is equipped with an encryption function 1 T...

Страница 18: ...tion that suppresses the power consumption of hardware that has a low usage rate The function suppresses operation of hardware that has a low usage rate and reduces power consumption by switching to power saving mode 1 Understanding an Overview of the System The power savings of the device have been achieved with a new implementation technology The SPARC M12 supports low power consumption to save ...

Страница 19: ...2 External Views of the Chassis This chapter shows external views of the chassis for each model ...

Страница 20: ... 1 2 External Views of the Chassis Front view Rear view Disk drive Operation panel USB port POWER switch Mode switch Power supply unit XSCF LAN port SAS port 10GbE LAN port PCI Express slot USB port XSCF USB port 19 ...

Страница 21: ... Fan unit 1 Disk drive Operation panel USB port POWER switch Mode switch 1 You can check the fan unit by removing the front cover Front view Power supply unit XSCF LAN port SAS port 10GbE LAN port PCI Express slot USB port XSCF USB port Rear view 20 ...

Страница 22: ...an check the fan unit by removing the front cover Front view Rear view Fan unit 1 Disk drive Operation panel USB port POWER switch Mode switch Power supply unit XSCF LAN port SAS port 10GbE LAN port PCI Express slot USB port XSCF DUAL control port XSCF USB port XSCF BB control port 21 ...

Страница 23: ...I Expansion Unit Expansion Option 2 External Views of the Chassis 1 You can check the fan unit by removing the front cover Front view Rear view Power supply units Link board PCI Express slot Fan unit 1 LED 22 ...

Страница 24: ...ibes the server and processor hardware specifications For details on firmware and software see Chapter 1 Understanding an Overview of the SPARC M12 M10 in the Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 System Operation and Administration Guide ...

Страница 25: ...ber of slots number of connected PCI expansion units 1 CPU mounted 33 slots 3 units 2 51 slots 4 units 2 48 slots 4 units 2 2 CPUs mounted 91 slots 8 units 2 88 slots 8 units 2 3 1 Server Specifications 3 System Specifications 1 To mount a 64 GB DIMM see Notes on Memory in the Fujitsu SPARC M12 Product Notes 2 If the OS versions of the control domain root domains and I O domains are all Oracle Sol...

Страница 26: ... Active replacement facility Built in disk drive 2 SSD 3 power supply unit fan unit Built in disk drive 2 SSD 3 power supply unit fan unit PCIe card 4 Built in disk drive 2 SSD 3 power supply unit fan unit PCIe card 4 XSCF unit 5 Supported OS Oracle Solaris 10 11 or later 3 1 Server Specifications Continued 3 System Specifications 1 When memory is mirrored 2 When the disk is mirrored by software o...

Страница 27: ...ber of PCIe ports 4 DVFS Supported CPU core degradation Supported DIMM degradation Supported FTL lane degradation Supported Power supply noise measure Operation rate modulation frequency modulation SWoC SIMD Single Instruction Multiple Data Can process up to 64 values of 4 bit data simultaneously per core Decimal floating point arithmetic unit mounted Conforms to IEEE 754 2008 standard for decimal...

Страница 28: ...ility Power supply unit fan unit PCIe card 1 link board 2 1 Active replacement may not be possible depending on the PCIe card type 2 You can replace the board after disconnecting the link card connected to the PCI expansion unit or the physical partition containing this link card Use PCI Hot Plug to disconnect the card or dynamic reconfiguration DR to disconnect the physical partition 27 ...

Страница 29: ...uide by Phase Purpose This chapter shows the reference manuals for each work item from SPARC M12 installation to operation administration and system expansion For a list of the manuals and their formal names see 5 Document List ...

Страница 30: ...tware License Conditions Safety and Compliance Guide Security Guide Common Installation Planning Manual XSCF Reference Manual XSCF MIB and Trap Lists Service Manual External USB DVD Drive User Guide RCIL User Guide Product Notes Domain Configuration Guide System Operation and Administration Guide Installation Guide Installation Guide PCI Card Installation Guide PCI Card Installation Guide 29 ...

Страница 31: ...ystem design confirm the flow for system settings and system configuration 4 Document Map Reference Guide by Phase Purpose Quick Guide this document Common Installation Planning Manual Installation Guide Software License Conditions Getting Started Guide Important Legal and Safety Information Safety and Compliance Guide Security Guide Product Notes Installation Guide PCI Card Installation Guide Sys...

Страница 32: ...the entire system Make settings to improve reliability by using memory mirroring and the hardware RAID function c System configuration If you are not going to use the preinstalled Oracle Solaris as is install Oracle Solaris You can configure a virtual environment by dividing the system into physical partitions and logical domains 4 Document Map Reference Guide by Phase Purpose Installation Guide P...

Страница 33: ...est versions The updates require a service contract with Fujitsu s Support Desk c Failure diagnosis unit replacement If an error message appears on the console or the CHECK LED on the server or a peripheral device goes on diagnose whether a failure has occurred After a failure occurs replace the faulty unit The maintenance method varies with the unit A service engineer performs the maintenance wor...

Страница 34: ...block configuration In the building block method you can flexibly expand downscale the system by expanding reducing the SPARC M12 2S d Changing the resource configuration You can change the virtual CPU virtual memory and virtual I O configuration by using the dynamic reconfiguration function of Oracle VM Server for SPARC 4 Document Map Reference Guide by Phase Purpose System Operation and Administ...

Страница 35: ...s a list of documents related to the SPARC M12 Global site http www fujitsu com global products computing servers unix sparc downloads manuals Japanese site http www fujitsu com jp products computing servers unix sparc downloads manual ...

Страница 36: ... Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 Important Legal and Safety Information Describes software license agreements user license agreements and safety precautions Check this document before opening a software product package or installing the server Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 Safety and Compliance Guide Describes notes on server installation Check this document before instal...

Страница 37: ...ed in the system Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 System Operation and Administration Guide Describes items related to the management and maintenance work after operation has begun For domain settings see the Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 Domain Configuration Guide For the maintenance procedures for each field replaceable unit FRU see the Fujitsu SPARC M12 2 2S Service Man...

Страница 38: ...al Describes the information to be checked in system maintenance of the crossbar box and the maintenance procedures for each field replaceable unit FRU PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 Service Manual Describes the information to be checked in system maintenance of the PCI expansion unit and the maintenance procedures for each field replaceable unit FRU Fujitsu SPA...

Отзывы: