Table
B-1
Cards
That
Support
PHP/DR
(Fujitsu
Product
ID)
(continued)
Category
Name
Product
ID
Driver
Name
Software
Product
Name
PHP:
PCI
Hot
Plug
DR:
Dynamic
Reconfiguration
Path
Redundancy
Software
Active
Replace
ment
Active
Addition
Active
Replace
ment
Active
Addition
Suspend/
Resume
Processing
Time
(*1)
Infini
Band
Dual
Port
InfiniBand
4x
QDR
card
SP1X7B
A12F
hermon
Not
suppo
rted
Not
suppo
rted
Not
suppo
rted
Not
suppo
rted
-
Oracle
Solaris
standard
multi-path
function
(IPMP)
Graphic
Graphics
card
SP0X7G
R1F
mko
(TSI)
Not
suppo
rted
Not
suppo
rted
Not
suppo
rted
Not
suppo
rted
-
None
*1
The
suspend/resume
processing
time
means
the
time
required
for
the
suspend/resume
processing
per
PCI
card.
Calculate
the
total
suspend/resume
processing
time
for
the
PCI
cards
to
be
used.
*2
Supported
by
Oracle
Solaris
11.2
SRU
11.2.2.8.0
and
later
and
Oracle
Solaris
10
1/13
150400-18
and
later.
*3
Add
up
the
suspend/resume
processing
time
for
all
the
PCI
cards
mounted
in
the
PCI
expansion
unit.
*4
In
a
configuration
that
uses
this
card
to
assign
SR-IOV
(VF),
DR
is
restricted.
*5
In
2x40
mode
or
2x2x10
mode,
the
root
domain
must
be
restarted
because
the
QCU
tool
is
used
to
switch
modes.
*6
To
use
the
Ethernet
function
(qlcnic
driver)
in
Oracle
Solaris
10,
apply
149167-07
or
later.
*7
When
the
suspend/resume
processing
occurs
as
the
port
is
being
linked
up,
it
takes
about
3
seconds
with
a
1-port
card
and
about
5
seconds
with
a
2-port
card.
*8
Immediately
after
active
addition
of
the
PCI
expansion
unit,
active
addition
of
this
card
using
PHP
to
the
PCI
expansion
unit
is
not
possible.
*9
The
processing
time
for
each
card
is
10
seconds
in
Oracle
Solaris
11.3
or
later
and
Oracle
Solaris
10
1/13
149173-06
or
later.
*10
Active
addition
and
active
replacement
of
the
PCI
expansion
unit
are
not
possible.
*11
Supported
by
Oracle
Solaris
11.3
and
later.
Table
B-2
Cards
That
Support
PHP/DR
(Oracle
Product
ID)
Category
Name
Factory-
Mounted
When
Shipped
(Expanded
on
Site)
Driver
Name
Software
Product
Name
PHP:
PCI
Hot
Plug
DR:
Dynamic
Reconfiguration
Path
Redundancy
Software
Active
Replace
ment
Active
Addition
Active
Replace
ment
Active
Addition
Suspend/
Resume
Processing
Time
(*1)
Link
Link
card
kit
7105513
(7105576)
None
Suppo
rted
Suppo
rted
(*2)
Suppo
rted
Suppo
rted
0.1
sec.
(*3)
None
LAN
Sun
Dual
Port
GbE
PCIe
2.0
Low
Profile
Adapter,
MMF
7100482
(7100481)
igb
Suppo
rted
Suppo
rted
To
be
supported
Oracle
Solaris
standard
multi-path
function
(IPMP)
Sun
Quad
Port
GbE
PCIe
2.0
Low
Profile
Adapter,
UTP
7100479
(7100477)
igb
Suppo
rted
Suppo
rted
Suppo
rted
Suppo
rted
0.8
sec.
Appendix
B
Cards
That
Support
PCI
Hot
Plug
and
Dynamic
Reconfiguration
43
Содержание SPARC M12
Страница 1: ...Fujitsu SPARC M12 PCI Card Installation Guide Manual Code C120 0047 02EN July 2017 ...
Страница 40: ...Fujitsu SPARC M12 PCI Card Installation Guide July 2017 32 ...
Страница 54: ...Fujitsu SPARC M12 PCI Card Installation Guide July 2017 46 ...
Страница 60: ...Fujitsu SPARC M12 PCI Card Installation Guide July 2017 52 ...
Страница 64: ...Fujitsu SPARC M12 PCI Card Installation Guide July 2017 56 ...