54
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
FIGURE:
SunVTS Browser Interface
4. (Optional) Select the test category you want to run.
The following are test categories that are recommended for running on this server.
5. (Optional) Customize individual tests.
Click on the name of the test to select and customize individual tests.
Note –
Use the System Excerciser – High Stress Mode to test system operations. Use
the Component Stress – High setting for the highest stress possible.
SunVTS Tests
Field Replaceable Units Exercised by Tests
Memory Test
FB-DIMMs
Processor Test
CMP, motherboard
Disk Test
Disks, cables, disk backplane, DVD drive
Network Test
Network interface, network cable, CMP, motherboard
Interconnect Test
Board ASICs and interconnects
IO Ports Test
I/O (serial port interface), USB subsystem
Environment Test
Motherboard and service processor