Servicing Power Supplies
137
Related Information
■
“Servicing Power Distribution Boards” on page 163
■
“Servicing Power Supply Backplanes (SPARC Enterprise T5240 Servers)” on
page 170
■
“Remove a Power Supply” on page 137
■
“Install a Power Supply” on page 140
▼
Remove a Power Supply
Caution –
Hazardous voltages are present. To reduce the risk of electric shock and
danger to personal health, follow the instructions.
1. Move to the rear of the server chassis so you can view the power supply status
LEDs.
The amber Fault LED on the failed power supply will be on.
2. (Optional) You can verify the status indicated by the Fault LED by
running the
ILOM
show faulty
command.
The Fault LED indication is verified if the
show faulty
command lists that
power supply as faulty.
3. Locate and release the cable management arm (CMA).
a. Press and hold the tab as show in the following figure.
b. Rotate the cable management arm out of the way so that you can access the
power supply.