Processors
Replacing the processor
6.2
Replacing the processor
V
CAUTION!
Only processors of the same type may be used on the system board.
That means the number of the internal processor cores as well as the
primary clock and the FSB frequency have to be the same. For dual
operation, use a suitable multiprocessor operating system.
Ê
Open the server and remove the fan carrier as described in the
chapter
"Preparation" on page 27
.
Removing the heat sink
Figure 20: Removing the heat sink
Ê
Press the heat sink retaining clips downward and inward.
Ê
Fold back the heat sink retaining clips (1).
Ê
Loosen the heat sink by turning it back and forth and then lift it out (2).
Ê
Remove the residual thermal paste from the underside of the heat sink.
Ê
Clean the underside of the heat sink using a lint-free cloth.