TX200 S5
Options Guide
27
Preparation
System fans
4.3.1
Removing system fan 2 (or 2&4)
Figure 9: Example: Removing system fan 2&4
Ê
Disconnect the fan cable from the connector FAN2 (if there is a second fan
cable, disconnect this from FAN4) on the system board (see the technical
manual for the system board D2709 on the PRIMERGY ServerView Suite
DVD 2).
Ê
Press the two green locks of the air duct together (1).
Ê
Press the green lock of the air duct in the direction of the arrow (2).
Ê
Lift the air duct with the integrated system fan 2 (or 2&4) up and out (3).