4.4
Getting access to the component
4.4.1
Safety notes
CAUTION
▶
Only for non-hot plug components:
●
Before removing or attaching covers, turn off the server, all
peripheral devices, and any other connected devices.
●
Because there is a risk of electric shock or damage, please
disconnect all power cords from the outlet.
▶
The top cover must be replaced as soon as possible for purposes
of cooling, to comply with EMC regulations (regulations regarding
electromagnetic compatibility) and to prevent fires.
▶
"Important information" on page 31
.
▶
Only valid for the floorstand model:
Do not lift the server by the
front cover in order not to damage the locking clips.
4.4.2
Rack model
4.4.2.1
Extending the server out of the rack
CAUTION
▶
Use the anti-tilt plate to prevent the rack from tipping when
installing the rack. Pulling the server out of the rack without having
installed the anti-tilt plate may cause the rack to tip over.
▶
Be careful not to pinch fingers or clothes when sliding out the
server or pushing it back. Failure to do so may cause injury.
▶
"Important information" on page 31
.
▶
Remove all remaining external cables from the I/O panel and expansion
cards.
▶
If you are not using a cable management arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Basic hardware procedures
50
Upgrade and Maintenance Manual
TX1330 M4
Содержание PRIMERGY TX1330 M4
Страница 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Страница 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 412: ... Resuming BitLocker functionality on page 121 Front panel 412 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 478: ...Figure 315 Removing the intrusion switch holder A Cabling 478 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 520: ...FUJITSU Server PRIMERGY TX1330 M4 Reference Manual Reference Manual English Cable Plan for April 2022 ...
Страница 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...