232
Upgrade and Maintenance Manual
TX1310
M3
Appendix
17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
"Shutting down the server" on page 44
Ê
"Disconnecting the power cord" on page 45
Ê
Take the system down to its minimum startup configuration.
Ê
"Connecting the power cord" on page 56
Ê
Connect a display to the server.
Ê
"Switching on the server" on page 57
Field Replaceable Units (FRU)
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with heat sink
installed in CPU1
1 CPU fan
1 memory module
installed in slot CHA1
1 PSU
installed in PSU1
Table 7: Minimum startup configuration - components
Cable
Notes
Power cable
Table 8: Minimum startup configuration - cables
Содержание PRIMERGY TX1310 M3
Страница 6: ...Upgrade and Maintenance Manual TX1310 M3 Version history ...
Страница 28: ...28 Upgrade and Maintenance Manual TX1310 M3 Before you start ...
Страница 42: ...42 Upgrade and Maintenance Manual TX1310 M3 Important information ...
Страница 60: ...60 Upgrade and Maintenance Manual TX1310 M3 Basic hardware procedures ...
Страница 94: ...94 Upgrade and Maintenance Manual TX1310 M3 Hard disk drives HDDs ...
Страница 154: ...154 Upgrade and Maintenance Manual TX1310 M3 Processor CPU ...
Страница 174: ...174 Upgrade and Maintenance Manual TX1310 M3 Front panel and front USB ...
Страница 204: ...204 Upgrade and Maintenance Manual TX1310 M3 System board and components ...
Страница 234: ...234 Upgrade and Maintenance Manual TX1310 M3 Appendix ...