background image

8

Service Supplement

 TX100 

S1

Notational conventions

Introduction

1.2

Notational conventions

The following notational conventions are used in this manual:

Text in italics

indicates commands or menu items.

„Quotation marks“

indicate names of chapters and terms that are being 
emphasized.

Ê

describes activities that must be performed in the order 
shown.

V

CAUTION!

pay particular attention to texts marked with this symbol. 
Failure to observe this warning may endanger your life, 
destroy the system or lead to the loss of data.

I

indicates additional information, notes and tips.

Table 2: Notational conventions

Содержание PRIMERGY TX100 S1

Страница 1: ...PRIMERGY TX100 S1 Server Service Supplement Edition August 2009 ...

Страница 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2009 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to...

Страница 3: ...es 17 4 1 Preparation 17 4 1 1 Opening the server 17 4 1 2 Removing the air duct 18 4 1 3 Opening the front panel 18 4 2 Replacing the front panel cable 19 4 3 Replacing the USB front cable 25 4 4 Replacing the system fan 1 27 4 5 Replacing the system fan 2 29 4 6 Replacing the power supply unit 31 4 7 Replacing the processor 35 4 8 Replacing the system board 40 Index 45 ...

Страница 4: ......

Страница 5: ...ating Manual the Options Guide and the Technical Manual of the system board The activities described in this manual may only be performed by service personnel Service DVD Service partners of Fujitsu Technology Solutions can order a Service DVD PRIMERGY On the DVD the following manuals are available in pdf format The Safety notes and other important information manual The Operating Manual for PRIME...

Страница 6: ...e server Troubleshooting Information about the system board Features of the system board Board layout Switches LED displays Replacing the battery Technical Manual Extensions and upgrades I For some components only the installation routine is described in the Options Guide Removing these components proceed in reverse order Extending replacing the main memory Installing an accessible 5 25 inch drive...

Страница 7: ...ating panel cable Replacing the USB front cable Replacing the system fan 1 Replacing the system fan 2 Replacing the power supply unit Replacing the processor Replacing the system board Service Supplement Board layout BIOS setup BIOS Setup Information procedure Manual Table 1 Overview of the documentation TX100 S1 ...

Страница 8: ...tems Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips Table 2 Notational conventions ...

Страница 9: ...eed the Operating Manual for the server the Options Guide for the server and the Technical Manual for the system board Ê Shut down the server correctly switch it off pull out the power plug and open the server as described in the chapter Replacement routines on page 17 Ê Replace the defective component as described in the relevant chapter Ê Close the server 1 Ê Connect the cables 1 Ê Connect the s...

Страница 10: ......

Страница 11: ...he machine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed Transport the device only in the original packaging or in packaging that protects it from knocks and jolts Installation and operation V CAUTION This unit should not be operated in ambient temperatures above...

Страница 12: ...eripheral device e g memory subsystem fails during a power outage Data cables must be adequately shielded The EN 50173 and EN 50174 1 2 standards apply for LAN cabling The minimum requirement is the use of a category 5 screened LAN cable for 10 100 Mbit s Ethernet or a category 5e cable for Gigabit Ethernet The requirements from the ISO IEC 11801 specification must also be met Route the cables in ...

Страница 13: ...ey may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception hot pluggable power supply units can be replaced The ...

Страница 14: ...th the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Working with CDs DVDs and CD DVD drives When working with devices with CD DVD drives these instructions must be followed V CAUTION Only use CDs DVDs that are in perfect condition in your server s CD DVD drive in order to prevent data loss equipment damage and injury Check each CD ...

Страница 15: ... remove them after use Store the CDs DVDs in suitable sleeves Protect the CDs DVDs from exposure to heat and direct sunlight Laser information The CD DVD drive complies with IEC 60825 1 laser class 1 V CAUTION The CD DVD drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remo...

Страница 16: ...s discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction paths ...

Страница 17: ...em has not switched off the server press the on off button Ê Switch off the power supply unit use the master switch and disconnect the power plug from the grounded shockproof socket Ê If required remove the lock on the side cover Ê Lay the server on its left side as seen from the front Removing the side cover Ê Pull the locking lever as far as it will go Ê Lift up the side cover and remove it Lift...

Страница 18: ...nhook the cables from the brackets on the air duct Ê Remove any connected cables that are impeding your work Ê Unlock the air duct Ê While keeping the locking clip pressed lift the air duct out of its housing 4 1 3 Opening the front panel Open the front panel when making the following replacement routines Replacing the front panel cable Replacing the USB front cable Ê Remove the side cover as desc...

Страница 19: ...the hooks on the other side are unlocked V CAUTION The front panel cable is connected directly to the front panel If you are not careful when you open the front panel you may damage the front panel cable 4 2 Replacing the front panel cable Ê Open the server as described in section Preparation on page 17 Ê Remove the system fan 1 as described in section Replacing the system fan 1 on page 27 ...

Страница 20: ...20 Service Supplement TX100 S1 Replacing the front panel cable Replacement routines Figure 4 Disconnecting front panel cable Ê Disconnect the front panel cable T26139 Y3701 V117 from the system board ...

Страница 21: ...Replacement routines Replacing the front panel cable Figure 5 Front panel cable assembled Ê Release the cable clamp and pull out the front panel cable Ê Open the front panel as described in section Opening the front panel on page 18 ...

Страница 22: ...Supplement TX100 S1 Replacing the front panel cable Replacement routines Figure 6 Releasing the control elements Ê Release the On Off button and pull it out of the plastic part Ê Repeat the steps for the two LEDs ...

Страница 23: ... Service Supplement 23 Replacement routines Replacing the front panel cable Figure 7 Removing the front panel cable Ê Pull out slowly the front panel cable and thread the connector carefully through the recess ...

Страница 24: ...ble Ê Install the new front panel cable in the reverse order For the right position see figure 8 Ê Close the front panel Ê Reinstall the system fan 1 Ê Close the server and reconnect the power plug Pos Kabel Bedeutung 1 black red hard disk activity indicator 2 black green power on indicator 3 black blue On Off button Ԙ ԙ Ԛ ...

Страница 25: ...cable 4 3 Replacing the USB front cable Ê Open the server and the front panel as described in section Preparation on page 17 Ê Detach the USB front cable T26139 Y3894 V513 from the connector USB9 10 on the system board Figure 9 USB front cable removing screw Ê Remove the screw ...

Страница 26: ...and pull out carefully the USB front cable from the chassis Ê Thread the new cable through the recess and engage the connector mounting plate Ê Fasten the connector mounting plate with the screw Ê Reconnect the USB front cable T26139 Y3894 V513 to the connector USB9 10 on the system board Ê Close the front panel Ê Close the server and reconnect the power plug ...

Страница 27: ...ng the system fan 1 Ê Open the server and remove the air duct as described in section Prepa ration on page 17 Ê Disconnect the system fan cable from the connector FAN1 SYS on the system board Figure 11 Removing system fan 1 removing screws Ê Remove the two screws on the bottom of the server ...

Страница 28: ...ng it in the direction marked and take it out the chassis Ê Place the new system fan 1 and push it under the hooks until it engages Ê Fasten the system fan with the two screws on the bottom of the server Ê Connect the fan cable to the connector FAN1 SYS on the system board Ê Reinstall the air duct Ê Close the server and reconnect the power plug ...

Страница 29: ... fan 2 is only installed if the server is equipped with four hard disk drives Ê Open the server as described in section Opening the server on page 17 Ê Detach the unlocking lever and remove the system fan 2 Figure 13 Detaching system fan 2 Ê Disconnect the system fan cable from the connector FAN3 SYS on the system board ...

Страница 30: ...Installing system fan 2 Ê Connect the fan cable to the connector FAN3 SYS on the system board Ê Place the new system fan 2 in the two recesses on the server s bottom and press it in the direction of the arrow until it clicks audibly into place Ê Close the server and reconnect the power plug ...

Страница 31: ...er supply unit Ê Open the server as described in section Opening the server on page 17 Ê Disconnect all power supply cables from the system board and from the drives see the cabling in the Options Guide Figure 15 Detaching the power supply Ê Remove the four screws and pull out the power supply unit inward ...

Страница 32: ...acing the power supply unit Replacement routines Figure 16 Power supply carrier four screws Ê Remove the four screws Figure 17 Power supply carrier one screw Ê Remove the screw and take the power supply unit off the power supply carrier ...

Страница 33: ... unit Ê Mount the new power supply unit onto the power supply carrier similarly When mounting the power supply unit it has to be engaged in the corresponding hooks The power supply unit has to be engaged in the chassis on the bottom side Figure 18 Chassis hook on the bottom side ...

Страница 34: ...ounted power supply unit in the chassis I Make sure that the power supply unit engages Ê Secure the power supply unit at the rear of the server with the four screws see also figure 15 on page 31 Ê Connect all power supply cables to the system board and to the drives see the cabling in the Options Guide Ê Close the server and reconnect the power plug ...

Страница 35: ...or from its socket place it with its smooth side down on a non conducting antistatic surface Never push a processor over a surface Ê Open the server and remove the air duct as described in section Prepa ration on page 17 Figure 20 Removing heat sink Ê Loosen the four screws in a crossover pattern Ê Loosen the heat sink by turning it back and forth and then lift it out Ê Remove the residual thermal...

Страница 36: ...ment TX100 S1 Replacing the processor Replacement routines Figure 21 Removing old processor 1 Ê Release the spring clip by pressing it sideways and pull it upward as far as it will go 1 Ê Open the processor holder 2 Ԙ ԙ ...

Страница 37: ...TX100 S1 Service Supplement 37 Replacement routines Replacing the processor Figure 22 Removing old processor 2 Ê Lift the installed processor carefully out of the socket ...

Страница 38: ...etween your thumb and index finger and align it at the socket coding Ê Place the new processor in the socket with great care V CAUTION Do not bend the spring contacts of the processor socket Never touch the underside of the processor Even light contaminants such as oil from human skin can destroy the processor or impair its functionality ...

Страница 39: ...lose the processor holder Ê Lock the processor in place in the socket by returning the spring clip to its original position Ê Apply a small amount of thermal paste to the upper side of the new processor Ê Ensure a thin and even distribution of the thermal paste Ê Position the heat sink carefully on the processor ...

Страница 40: ...g straight 3 Finish tightening the four screws in a crossover pattern Ê Close the server install the air duct and reconnect the power plug 4 8 Replacing the system board I The system board can optionally be equipped with a TPM Trusted Platform Module This module enables third party programs to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated ...

Страница 41: ...ribed in section Prepa ration on page 17 Ê Lay the server on its left side as seen from the front Ê Remove all external cables Ê Remove the system fan 2 as described in section Replacing the system fan 2 on page 29 Ê Remove all controllers from their slots for a description see the Operating Manual and the Options Guide Take note of the slots of the controllers and the cabling Ê Remove the heat si...

Страница 42: ...ld of the heat sinks Ê Carefully lift the system board out of the housing in a slight angle Thereby you pull the connectors out of the connector panel Ê Check the settings on the new system board for a description see the Technical Manual of the system board Ê Insert the system board by holding it at a slight angle Slide the connectors into the connector panel V CAUTION Don t damage the EMI spring...

Страница 43: ...ptions Guide Ê Reinstall the system fan 2 as described in section Replacing the system fan 2 on page 29 Ê Install the air duct close the server and reconnect the power plug Ê Connect all external cables Ê If applicable activate TPM functionality in the system BIOS under Security TPM Security Chip Setting Security Chip For further information please refer to the BIOS manual V CAUTION After installi...

Страница 44: ......

Страница 45: ...e 16 F front panel 18 front panel cable 19 L laser information 15 light emitting diode LED 15 lithium battery 14 M meaning of the symbols 8 N notational conventions 8 P power supply unit 31 processor 35 S side cover 17 system board 40 system fan 1 27 system fan 2 29 T target group 5 U USB front cable 25 ...

Страница 46: ......