![Fujitsu PRIMERGY SX940 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/fujitsu/primergy-sx940/primergy-sx940_manual_121199034.webp)
34
Review
SX940
Mixed installation
Different configurations
5.3
Mixed installation
In a mixed installation with different controllers the following controller configu-
ration has to be observed:
1. LSI 1078 controller within mounting location for controller #1 (lower location)
2. LSI 1064 controller within mounting location for controller #2 (upper location)
Ê
Remove the storage blade as described in
section “Removing the storage
blade” on page 13
.
Ê
Open the storage blade as described in
section “Opening the storage blade”
on page 14
.
Prerequisites
No controller installed, HDDs not connected.
Figure 20: Mischbestückung
Cabling of controller #1 (LSI 1078
Ê
Plug the controller into the contact strip (1) of the main board #1 and fix it
with a screw C26192-Y10-C68 (blue circle).
Ê
Plug the connector HOST of the lower SAS cable into the SAS connector
MLC1 (2) on the controller #1.
Ê
Plug the connector P1 of the lower SAS cable into the connector on the HDD
diskbay 2/3 (3).
2
1
3
4
5