251
PRIMERGY RX300 S4 User's Guide
C Remote Control Function
This server supports a remote control function.
When a personal computer (PC) is connected to the serial port of this server with an
RS-232C cross cable, the PC can be used to control (turn on/off and reset) the server
power supply (remote control).
C.1
Preparation for Using Remote Control Function
To enable the remote control function, perform the procedures in the following sections.
• Configuring the BIOS
• Connecting the Server to a PC
• Configuring the Terminal Software (PC)
Configuring the BIOS
To use the function of the server management port, perform the following setting using the BIOS Setup
Utility.
1
Turn on the server. Press the [F2] key during POST to start up the BIOS Setup
Utility.
2
Select [Peripheral Configuration] from the [Advanced] menu, and set the
following items.
• Set [Serial 1] to [Disabled]
• Set [Serial Multiplexer] to [iRMC]
3
Select [Saving Changes & Exit] in the [Exit] menu to exit the BIOS Setup Utility.
Содержание Primergy RX300 S4
Страница 12: ...12 ...
Страница 38: ...38 Chapter 1 Overview ...
Страница 72: ...72 Chapter 3 OS Installation ...
Страница 124: ...124 Chapter 4 Operations after OS Installation ...
Страница 132: ...132 Chapter 5 High Reliability Tools ...
Страница 180: ...180 Chapter 6 Installing Internal Options ...
Страница 266: ...266 ...