220
Upgrade and Maintenance Manual
TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
7.3.10 Removing 3.5-inch HDD modules
7.3.10.1 Preliminary steps
Ê
If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs in the RAID array will be lost when deleting a
RAID array! Be sure to back up your data before deleting a RAID
array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result in
data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array will
not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
.
Содержание PRIMERGY RX2560 M2
Страница 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Страница 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Страница 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Страница 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Страница 282: ...282 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Hard disk drive HDD solid state drive SSD ...
Страница 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Страница 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Страница 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Страница 508: ...508 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Converting a tower model to a rack model ...
Страница 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Страница 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...