RX2530 M4
Upgrade and Maintenance Manual
25
2
Before you start
Before you start any upgrade or maintenance task, proceed as follows:
Ê
Carefully read the safety instructions in chapter
Ê
Make sure that all necessary manuals are available, see the documentation
overview in section
"Documentation overview" on page 31
. Print the PDF
files if required.
Ê
Make yourself familiar with the procedure categories introduced in section
"Classification of procedures" on page 27
Ê
Ensure that all required tools are available according to section
Advanced Thermal Design (ATD)
The ATD option allows you to operate the system with a wider temperature
range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on your system and
configuration.
V
CAUTION
In a system that is configured with ATD, only certain components which
support the respectively increased higher operating temperature range
may be installed and used. For applicable restrictions, see the official
configurator tool.
Installing optional components
The operating manual of your server gives an introduction to server features
and provides an overview of available hardware options.
Use the Fujitsu ServerView Suite management software and the iRMC web
interface to prepare hardware expansions. ServerView Suite documentation is
available online at
.
For Japan:
http://www.fujitsu.com/jp/products/computing/servers/primergy/manual/
This option can only be ordered from the
manufacturer and is indicated by the respective
logo on the identification rating plate.
Содержание PRIMERGY RX2530 M4
Страница 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Страница 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Страница 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Страница 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Страница 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Страница 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Страница 322: ...322 Upgrade and Maintenance Manual RX2530 M4 Liquid cooling LC Figure 231 Routing the tubes Ê Run the tubes as shown ...
Страница 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Страница 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Страница 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Страница 439: ...FUJITSU Server PRIMERGY RX2530 M4 Reference Manual Reference Manual English Cable plan for September 2018 ...
Страница 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...