106
Upgrade and Maintenance Manual
RX2530 M4
Basic software procedures
5.2.19 Switching off the ID indicator
Press the ID button on the front panel, or use the iRMC web interface or
ServerView Operations Manager to switch off the ID indicator after the
maintenance task has been concluded successfully.
I
For more information, see section
"Locating the defective server" on
or the "ServerView Suite Local Service Concept (LSC)" and
"iRMC S5 - Web Interface" user guides.
Using the ID button on the front panel
Ê
Press the ID button on the front panel to switch off the ID indicators.
Using the ID icon in the RMC web interface
Ê
Log in to the iRMC S5 web interface.
The icon that represents the ID indicator LED resides on the right of the
menu bar. Its color symbolizes its status:
blue
: the ID LED is on.
grey
: the ID LED is off
Ê
Click the icon to switch the ID indicator LED on or off.
Using ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
and press the
Locate
button in the title bar to switch off the ID indicator.
5.2.20 Performing a fan test
I
Notes on replacing a defective fan
After replacing a defective system fan or PSU containing a defective fan,
the fan error indicators will stay lit until the next fan test. By default, a fan
test is automatically started every 24 hours. The first automatic fan test
being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Содержание PRIMERGY RX2530 M4
Страница 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Страница 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Страница 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Страница 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Страница 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Страница 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Страница 322: ...322 Upgrade and Maintenance Manual RX2530 M4 Liquid cooling LC Figure 231 Routing the tubes Ê Run the tubes as shown ...
Страница 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Страница 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Страница 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Страница 439: ...FUJITSU Server PRIMERGY RX2530 M4 Reference Manual Reference Manual English Cable plan for September 2018 ...
Страница 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...