When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed
.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Save & Exit
menu.
●
Select
Save Changes and Exit
or
Save Changes and Reset
.
●
Verify that the Global Error indicator stops flashing.
▶
"Resetting the error status after replacing memory modules or CPUs" on
page 78
.
▶
"Enabling replaced components in the BIOS" on page 82
▶
"Resuming BitLocker functionality" on page 88
11.4
Replacing a CPU or heat sink
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
CAUTION
CPUs are extremely sensitive to electrostatic discharge and therefore
must always be handled with care.
▶
After a CPU has been removed from its protective sleeve or from its
socket, place it upside down on a nonconducting, antistatic surface.
▶
Never push a CPU over a surface.
Processor (CPU)
282
Upgrade and Maintenance Manual
RX2520 M5
Содержание PRIMERGY RX2520 M5
Страница 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 296: ...Figure 177 Installing the ODD A Insert the ODD Accessible drives 296 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 301: ...Figure 181 Removing the ODD A Unlock the ODD latch 1 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 301 ...
Страница 343: ... Resuming BitLocker functionality on page 88 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 343 ...
Страница 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 427: ...Figure 280 Removing the system board System board and components RX2520 M5 Upgrade and Maintenance Manual 427 ...
Страница 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 464: ...FUJITSU Server PRIMERGY RX2520 M5 Reference Manual Reference Manual English Cable Plan for March 2022 ...
Страница 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...