After replacing a network controller or the system board, switch on and boot
the server, see
"Switching on the server" on page 57
The hardware configuration tool for Red Hat Linux, will launch at boot and
detect the new and/or changed hardware on your system.
▶
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
If the system board or network controller offers multiple LAN ports, it
is necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
▶
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.3.14
Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see
"Suspending BitLocker functionality" on page 65
to complete the service task.
▶
If applicable, ask the system administrator to enter the recovery key in order
to boot the OS.
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting
the server after the maintenance task. However, if BitLocker
functionality has not been suspended, Windows will enter recovery
mode and ask you to input recovery key for further booting.
▶
Ask the system administrator to enable the previously suspended BitLocker
protection on the system volume, using the
BitLocker Drive Encryption
control panel item:
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
Basic software procedures
88
Upgrade and Maintenance Manual
RX2520 M5
Содержание PRIMERGY RX2520 M5
Страница 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 296: ...Figure 177 Installing the ODD A Insert the ODD Accessible drives 296 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 301: ...Figure 181 Removing the ODD A Unlock the ODD latch 1 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 301 ...
Страница 343: ... Resuming BitLocker functionality on page 88 Accessible drives RX2520 M5 Upgrade and Maintenance Manual 343 ...
Страница 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 427: ...Figure 280 Removing the system board System board and components RX2520 M5 Upgrade and Maintenance Manual 427 ...
Страница 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Страница 464: ...FUJITSU Server PRIMERGY RX2520 M5 Reference Manual Reference Manual English Cable Plan for March 2022 ...
Страница 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...