142
Upgrade and Maintenance Manual
RX100
S8
Hard disk drives / solid state drives
7.3.3
Removing 3.5-inch HDD modules
7.3.3.1
Preliminary steps
Ê
If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up your
data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
"Performing a RAID array
rebuild" on page 85
.
Содержание PRIMERGY RX100 S8
Страница 18: ...Upgrade and Maintenance Manual RX100 S8 Contents ...
Страница 62: ...62 Upgrade and Maintenance Manual RX100 S8 Basic hardware procedures ...
Страница 148: ...148 Upgrade and Maintenance Manual RX100 S8 Hard disk drives solid state drives ...
Страница 154: ...154 Upgrade and Maintenance Manual RX100 S8 Fans ...
Страница 270: ...270 Upgrade and Maintenance Manual RX100 S8 System board and components ...
Страница 278: ...278 Upgrade and Maintenance Manual RX100 S8 Cables ...