U41615-J-Z156-1-76
47
Preparation for Use/Operation
Configuring the Server
Using Global Array Manager (GAM)
The
Write Cache
can only be enabled via the
RAID Assist
wizard of the Global
Array Manager while the configuration of the SATA RAID controller is performed.
Ê
Open the
RAID Assist
wizard and follow the instructions on the screen.
Ê
Set
Write Cache
to enabled.
You find more information in the “Global Array Manager Client Software User’s
Guide” (see also
“Related publications” on page 63
).
5.3.2
Configuration with ServerStart
With the
ServerStart
CD provided, you can configure the server and install the
operating system in a convenient manner.
The menu-guided configuration includes the SATA RAID controller configuration
with
GAM
(Global Array Manager, see
“Related publications” on page 63
I
SATA-ID
information:
Please note that the SATA IDs for the hot-plug hard disk drives are fixed
(from right to left in the order 0, 1).
I
Descriptions of operating systems not covered in the SATA RAID
controller manual are provided in the appropriate readme files on the
driver CDs.
To find out how to operate
ServerStart
and for further information, refer to the
corresponding
ServerStart
manual (see
“Related publications” on page 63
If you use
ServerStart
, you can skip the following section on how to configure the