Fujitsu PRIMERGY PG-R1CK7 Скачать руководство пользователя страница 58

5

E

Conversion procedure

The following is the procedure to convert the server from a deskside model to a rackmount
model.

When installing or removing hardware options from the server,
turn off the server, all peripheral devices, the server monitor
module, and any other the connected devices. Also unplug all
power cords. Failure to do so can lead to electric shock.

Contact your maintenance engineer to perform the conver-
sion.

For safety reasons, make sure the server is located on a sta-
ble and level surface when perform the conversion work as
the combined weight can be in excess of 30kg.

Also, work in an open space as the rackmount must be laid
horizontally to perform the conversion.

Make sure that the system is operating properly before per-
forming the conversion.

Devices inside the server remain hot after shutdown. Wait for
approximately 10 minutes after shutdown before installing or
removing hardware options from the server.

Static electricity can damage the internal hardware compo-
nents. Wear a wrist grounding strap when working inside the
server.

Do not touch any panel circuitry. Hold the metallic areas or
the green areas of the circuit boards.

Содержание PRIMERGY PG-R1CK7

Страница 1: ...このマニュアルは再生紙を使用しています PRIMERGY P3FY 2170 01 E マニュア 製品名称 PRIMERGY C200 FileServer PGC2CL1QA PGC2CP1QA ラックマウント変換機構 PG R1CK7 PGR1CK10 PRIMERGY C200 PGC2CL1QA PGC2CP1QA Rack Conversion Kit PG R1CK7 J E ...

Страница 2: ...C200 FileServer ラックマウント変換機構 PG R1CK7 PG R1CK10 をお買い上げいただき 誠にありがとうございます ラックマウント変換機構は デスクサイドタイプのサーバをラックに搭載するため に ラックマウントタイプに変換するためのキットです 本書はラックマウント変換機構の取り扱いの基本的なことがらについて説明してい ます 本書をご覧になり ラックマウント変換機構を正しくお使いいただきますよう お 願い致します 2002 年 3 月 ...

Страница 3: ...タイプがあります 以下のラック以外には サーバを搭載することができませんので ご注意ください スタンダードラック 型名 PG R3RC1 PG R3RC2 PG R4RC1 PG R4RC2 スリムラック 型名 GP5 R1RC6 GP5 R1RC7 GP5 R2RC3 GP5 R2RC4 会社名および製品名は 各社の商標または登録商標です All Rights Reserved Copyright 富士通株式会社 2002 スタンダードラック スリムラック ...

Страница 4: ...ために 上記の絵表示と同時に 次の記号を使用しています 警告 この表示を無視して 誤った取り扱いをすると 人が死亡する可能性 または重傷を負う可能性があることを示しています 注意 この表示を無視して 誤った取り扱いをすると 人が傷害を負う可能 性があること および物的損害のみが発生する可能性があることを示 しています で示した記号は 警告 注意を促す内容であることを告げるも のです 記号の中やその脇には 具体的な警告内容 左図の場合は感 電注意 が示されています で示した記号は してはいけない行為 禁止行為 であること を告げるものです 記号の中やその脇には 具体的な禁止内容 左図 の場合は分解禁止 が示されています で示した記号は 必ず従っていただく内容であることを告げる ものです 記号の中やその脇には 具体的な指示内容 左図の場合は 電源プラグをコンセントから抜いてください が示されて...

Страница 5: ... 感電したり機器が故障するおそれがあります 注意 指 示 サーバ本体をラックマウントタイプに変換するときは 必ず担 当営業員または担当保守員に連絡してください 禁 止 サーバ本体を直射日光の当たる場所や 暖房器具の近くな ど 高温になる場所には設置しないでください また 10 未満の低温になる場所では 運用しないでください 故 障の原因となります サーバ本体を塩害地域では使用しないでください 故障の 原因となります ラックの開口部 通風孔など をふさがないでください 通風孔をふさぐと内部に熱がこもり 火災の原因となりま す 電源ケーブルおよび各種ケーブル類に足がひっかかる場所 には設置しないでください 故障の原因となります サーバ本体をテレビやスピーカの近くなど 強い磁界が発 生する場所には設置しないでください 故障の原因となります ...

Страница 6: ...v J 注意 禁 止 空気の吸排気口である装置前面部および背面部をふさがな いでください これらをふさぐと内部に熱がこもり 火災の原因となりま す サーバ本体を移動する場合は 必ず電源を切断し ケーブ ル類 マウス キーボード AC ケーブルを外してくださ い オプションの搭載によって 最大 30Kg の重量となり ますので十分注意してください ...

Страница 7: ...vi ...

Страница 8: ...Shift キーなど コマンド入力 本文中では コマンド入力を次のように表記しています diskcopy a a の箇所のように文字間隔をあけて表記している部分は Space キー キーボード 手前中央にある何も書かれていない横長のキー を 1 回押してください また 上記のようなコマンド入力を英小文字で表記していますが 英大文字で入力 してもかまいません 本文中の表記 本文中では 以下の表記 記号を使用しています ラックマウント変換機構または本製品 PRIMERGY C200 FileServer ラックマウント変換機構のことです サーバ本体または本サーバ PRIMERGY C200 FileServer のことです 本書では 本サーバの形態を区別して 以下の名称を用いて説明しています ペデスタルタイプ ラックマウントタイプ ...

Страница 9: ...viii ...

Страница 10: ...カバーの取り外し 11 5 左サイドカバーの取り外し 12 6 フロントカバーの取り外し 13 7 右サイドカバーの取り外し 14 8 固定足の取り外し 15 9 各ドライブとオペレータパネルの入れ替え 16 10 フロントカバーブラケットの取り付け 19 11 フロントカバーの取り付け 19 12 左サイドカバーの取り付け 20 13 ラックフロントカバーの取り付け 20 14 サーバ本体のラックへの搭載 21 15 内蔵ハードディスクの取り付け 28 16 電源を入れる前の確認事項 29 17 Chassis ID の更新 30 付録 33 使用環境シート 33 ...

Страница 11: ...x ...

Страница 12: ...1 J 本製品の梱包物 ここでは 本製品に同梱されている部品を示します 作業を行う前に 以下のリストに従って部品がすべて揃っているかどうかを確認 し 万一足りない部品があった場合は担当営業員に連絡してください 部品 名称 数量 確認 ラックフロントカバー 1 レールブラケット 2 スライドレール 2 フロントカバーブラケット 2 ...

Страница 13: ...2 本製品の梱包物 ブラケット A 1 左右 各 1 ブラケット B 1 2 ブラケット C 1 2 M4 バインドネジ 14 M4 タップタイトネジ 8 M5 ネジ 1 8 部品 名称 数量 確認 Left Right ...

Страница 14: ...3 J 1 スリムラックへの搭載時のみ使用します 2 スタンダードラックへの搭載時のみ使用します M6 ネジ 1 4 M6 サラネジ 1 4 スクリューホルダー 1 4 M5 ラックナット 4 スプリングナット 2 4 部品 名称 数量 確認 ...

Страница 15: ...4 本製品の梱包物 ...

Страница 16: ...守員に連絡し 変換作業は必ず担当保 守員に行わせてください サーバのラックマウントタイプへの変換作業は 安定した 場所で行ってください オプションの搭載によって 最大 30kg の重量となりますので十分注意してください サーバのラックマウントタイプへの変換作業は サーバ本 体を横にして作業をするのに十分な広さの場所で行ってく ださい サーバをラックマウントタイプに変換する前に必ずシステ ムを起動し システムの動作状況を確認してください 電源を切った直後は サーバの内部の装置が熱くなってい ます 内蔵オプションの取り付けや取り外しを行う場合は 電源を切ったあと 10 分ほど待ってから 作業を始めてくだ さい 内蔵オプションは 基板や半田付けした部分がむきだしに なっています これらの部分は 人体に発生する静電気に よって損傷を受ける場合があります 取り扱う前に 添付 のリストストラップを必ず...

Страница 17: ...ーを取り外します 8 固定足を取り外します 9 各ドライブとオペレータパネルを入れ替えます 10 フロントカバーブラケットを取り付けます 11 手順 6 で取り外したフロントカバーを再び取り付けます 12 手順 5 で取り外した左側のサイドカバーを再び取り付けます 13 ラックフロントカバーを取り付けます 14 ラックマウント変換機構をサーバ本体に取り付け ラックへ搭載しま す 15 手順 3 で取り外した内蔵ハードディスクを再び取り付けます 16 電源を入れる前の確認を行います 17 Chassis ID を更新します 注意 必ず内蔵ハードディスクを取り外してください 作業中に内蔵 ハードディスクに衝撃が加わると 保存されているデータが損 傷することがあります ...

Страница 18: ...ま す 4 周辺機器が接続されている場合は 周辺機器の電源を切り サーバ本 体から取り外します 2 ハードディスクカバーの取り外し 1 ドライブカバーキーを左に回し ロックを解除します 注意 各カバーの取り外し 取り付けを行うときは 必ず添付のリス トストラップを着用してください リストストラップは 作業が終了するまで外さないでください 注意 ドライブカバーキーは装置ごとに異なります 紛失しないよう に注意してください 紛失した場合は ロック部の破壊が必要であり 部品の有償交 換となりますので ドライブカバーキーの管理については十分 ご注意願います なお 万一ドライブカバーキーを紛失された場合は 担当営業 員までご連絡ください ドライブカバーキー ...

Страница 19: ...8 操作方法 2 ドライブカバーを上方にスライドします 3 ハードディスクカバーを取り外します ハードディスクカバーを手前に倒 して 引き上げて取り外します ドライブカバー ...

Страница 20: ...付け る面 図中 B があります A 側のシールをはがして 図に示 すようにサーバ本体前面に接着し ます B 側は手首に巻き付けてく ださい 3 内蔵ハードディスクの取り外し 内蔵ハードディスクは ハードディスクカバーを取り外したあとにいったん取り外 します 取り外した内蔵ハードディスクは サーバ本体をラックに搭載したあと 再度取り付けます ここでは 内蔵ハードディスクの取り外しの手順について説明します A リストストラップ B 注意 指 示 サーバ本体を移動する前に 必ず内蔵ハードディスクを取り外 してください 内蔵ハードディスクに衝撃が加わると 保存さ れているデータが損傷することがあります ...

Страница 21: ...取り外し手順 1 内蔵ハードディスクを取り外します 取り外したい内蔵ハードディスク 前面のタブを押しながら A ハ ンドルを上側に開け 手前に引き ます B そのとき 内蔵ハード ディスクに手を添え 両手で持っ て引き出してください ペデスタルタイプ時正面図 FDD ベイ4 ID 3 ベイ1 CD ROM DVD ROM ベイ3 ID 6 注 ベイ2 ID 5 注 注 内蔵DDS4オートローダ PG DTA102 搭載時は SCSI IDを 5 に設定します ベイ3 ID 2 ベイ2 ID 1 ベイ1 ID 0 FDD ベイ4 ID 3 ベイ3 ID 2 ベイ2 ID 1 ベイ1 ID 0 ベイ1 CD ROM DVD ROM ベイ3 ID 6 注 ベイ2 ID 5 注 ラックマウントタイプ時正面図 ハンドル A B ...

Страница 22: ...4 ドライブカバーの取り外し 11 J 4 ドライブカバーの取り外し 1 ドライブカバーを下方に止まるところまでスライドします 2 ドライブカバー上部の両側のツメを押しながらドライブカバーを開き ます ドライブカバー ツメ ...

Страница 23: ...12 操作方法 3 ドライブカバーを矢印の方向に引いて取り外します 5 左サイドカバーの取り外し 1 サーバ本体の背面側 2 箇所の M3 ネジを取り外します 注意 取り外したネジは 左サイドカバーの取り付け時に使用します ので なくさないように注意してください ...

Страница 24: ...とサーバ背面にスライドさせ サーバ本体か ら取り外します サイドカバーを手前に倒して取り 外します 6 フロントカバーの取り外し 1 フロントカバーを取り外します フロントカバーは タブでサーバ 本体と固定されています サーバ本体左側の 3 箇所のタブを 外してから右側のタブを押しなが ら外し フロントカバーを取り外 します 2 フロントカバー裏側から M3 ネジ 3 本を外し ドライブカバーストッ パーを取り外します 左側タブ 右側タブ ドライブカバーストッパー ...

Страница 25: ...14 操作方法 7 右サイドカバーの取り外し 1 サーバ本体の背面側 2 箇所の M3 ネジを取り外します 2 右サイドカバーのツメの下にドライバーを差し込んで持ち上げ タブ から外します タブ ...

Страница 26: ...8 固定足の取り外し 15 J 3 右サイドカバーを後方に引いて取り外します 8 固定足の取り外し 1 サーバ本体を図のように横にします 2 サーバ本体底面の上部の固定足を取り外します 2 つの固定足をはがすようにして取り 外します ...

Страница 27: ...4 ネジ を外します 4 プレートを背面側にスライドさせ 手前に引いて取り外します 9 各ドライブとオペレータパネルの入れ替え ここでは CD ROM DVD ROM ドライブ 5 インチドライブ およびオペレー タパネルの入れ替えの手順について説明します ラックマウントタイプに変換するときは 5 インチストレージベイに搭載されてい るユニットとオペレータパネルを 向きを変えて入れ替えます 変換前 変換後 5インチドライブまたは 5インチブランクユニット CD ROM DVD ROM ドライブ オペレータパネル ...

Страница 28: ...ドライブから内部ケーブルおよび電源 ケーブルを取り外します 2 クランプから オペレータパネルのケーブルのみを取り外します 3 オペレータパネル 5 インチドライブまたは 5 インチブランクユニッ ト および CD ROM ドライブを 5 インチストレージベイから取り外し ます 上下のツメを内側に押しながら ゆっくりと手前に引き出します ポイント ポイント ポイント ポイント システム構成により 5 インチブランクユニットは搭載されて いない場合があります クランプ サーバ本体内部 ツメ 正面 ...

Страница 29: ...イブまたはチブランクユニッ ト CD ROM ドライブをベイに差 し込み カチッと音がするまで押し 込みます 5 イントリュージョンケーブルをコネクタから取り外します 6 CD ROM ドライブと 5 インチドライブに 内部ケーブルおよび電源 ケーブルを接続します 7 手順 2 で取り外したオペレータパネルのケーブルをクランプに戻して 留め付けます 注意 各ドライブや 5 インチブランクユニットを取り付けるときは ケーブル類をサーバ本体の部品にはさみ込まないように注意し てください ポイント ポイント ポイント ポイント システム構成により 5 インチブランクユニットは搭載されて いない場合があります イントリュージョンケーブル ...

Страница 30: ...フロントカバーブラケットの取り付け 1 フロントカバーブラケットを サーバ本体の両側に取り付けます 左右のブラケットは 各 2 箇所ずつ 本製品に添付の M4 タップタイトネ ジで固定します 11 フロントカバーの取り付け 1 6 フロントカバーの取り外し 13 ページ で取り外したフロント カバーを取り付けます サーバ本体下部にフロントカバーの 2 箇所のタブをはめ込んでから 上部 3 箇所のタブをはめて取り付けます 左側面 ネジ穴 上部のタブ 下部のタブ ...

Страница 31: ...ドカバーは 5 左サイドカバーの取り外し 12 ページ と逆の手順で取 り付けてください 13 ラックフロントカバーの取り付け 1 ラックフロントカバーを取り付けます 両側のフロントカバーブラケット に 本製品に添付の M4 タップタ イトネジ 4 本で固定します 注意 左サイドカバーを取り付けるまで リストストラップは外 さないでください 左サイドカバーを取り付けるときに サーバ本体内部に不 要な部品や工具を置き忘れたままにしないようにご注意く ださい ...

Страница 32: ...ックへの搭載までの手順について説明 します レールの取り付け手順は 使用するラックのタイプによって違います インナーレールの取り付け 1 インナーレールを ロックを押しながらスライドレールから引き出し て取り外します 2 インナーレールをサーバ本体の左右に取り付け 本製品に添付の M4 バインドネジで左右各 3 箇所を固定します 左右ともに インナーレール のロックの開いた部分が前面 側に来るように取り付けま す インナーレール スライドレール ロック インナーレール M4バインドネジ ロックの向き 前面側 後面側 ...

Страница 33: ...イドレールを図のようにスライドさせながら行い ます スライドさせるときは スライドレールのロックを少し引き上げて解除 します 右側のスライドレールは 図のレールブラケットの向きに対して前後が逆にな るように取り付けます サーバ本体の取り付け位置の選択 1 ラックのフロントドアとリアドアを開けます 2 サーバ本体を取り付ける位置を決めます 任意の ラック支柱の穴の間隔が狭い位置 にサーバ底面が来るように合わせます レールブラケット スライドレール スライドレールを引き出した 状態で固定 M4バインドネジ スライド方向 左側 ロック 矢印方向に持ち上げて解除 ラック支柱 サーバ本体底面の位置 ...

Страница 34: ...グナットをスライドさ せます 図中 5 2 レールとラックナットをラックに取り付けます 本サーバは 5U 使用します 1 左右のレールをラックに取り付けます レールの前後の外側にある 4 つの小突起をラック支柱の穴に引っ掛 け 手順 1 で取り付けたスプリングナットと本製品に添付の M5 ネジ 各 4 本で取り付けます 2 本製品に添付の M5 ラックナットを取り付けます サーバ本体を取り付ける位置の下から 3 個目と 13 個目の位置に ラックレールの内側からツメを引っ掛けて取り付けます 注意 ラックナットは ラックに添付のものではなく 本製品に添付 のものをご使用ください 2 3 45 4 5 1 5 M5ネジ 前面 3個目へ 13個目へ ラックナット 背面 M5ネジ サーバ本体底面 ...

Страница 35: ... 1 レールを組み立てます スライドレールにブラケット A B C を 本製品に添付の M5 ネジ前後各 2 本で取り付けます ブラケット A B は スライドレールの内側のツメをブラケットの穴に引っ掛 けてからネジをしめます 背面側のブラケットは ネジを軽くしめておきます ブラケットA スライド レール M5ネジ 左側 右側 前面 背面 ブラケットA ブラケットB ブラケットB ブラケットC ブラケットC スライド レール M5ネジ M5ネジ ツメ ツメ ...

Страница 36: ...クナットをラックに取り付けます 本サーバは 5U 使用します 1 レールを取り付けます レールはサーバ本体を取り付ける位置の下から 前面は 4 個目と 6 個 目の位置に本製品に添付の M6 サラネジのみで取り付けます 背面は スクリューホルダーとともに M6 ネジで取り付けます M6 ネジ ス クリューホルダーは本製品に添付 2 本製品に添付の M5 ラックナットを取り付けます サーバ本体を取り付ける位置の下から 3 個目と 13 個目の位置に ラックレールの内側からツメを引っ掛けて取り付けます ラック左側 ラック支柱 前面 背面 サーバ本体底面 前面 背面 4個目 6個目 M6サラネジ 13個目へ 3個目へ スクリュー ホルダー M6ネジ 6個目 1個目 ラックナット ...

Страница 37: ...26 操作方法 ラックへの搭載 1 スライドレールを カチッと音がするまで伸ばします 2 サーバ本体をスライドレールに取り付けます スライドレールの溝に サーバ本 体に取り付けたインナーレールの 溝を合わせて差し込みます 注意 ラックナットは ラックに添付のものではなく 本製品に添付 のものをご使用ください ...

Страница 38: ...バ本体のラックへの搭載 27 J 3 サーバ本体を後方にスライドさせ ラックに搭載します サーバ本体左右のレールのツメ を押して ロックを解除してか ら後方にスライドします 4 サーバ本体とラックを固定します サーバ本体とラックを 4 本のつま みネジで固定します 注意 サーバ本体をスライドさせる場合やロックを解除する場合は 指や衣服が挟まれないよう注意してください けがをするおそ れがあります ロック ロック ...

Страница 39: ...付け 1 内蔵ハードディスクをサーバ本体に取り付けます 内蔵ハードディスクのハンドルが上 げられた状態で 内蔵ハードディス クベイに差し込みます 内蔵ハードディスクのハンドルを下 げて 確実に差し込みます 注意 内蔵ハードディスクは 取り外したときに記録した位置と必ず 同じ位置に内蔵ハードディスクを取り付けてください 内 蔵ハードディスクの搭載位置についての注意 10 ページ 参照 取り付け位置が違うと正しく動作しないおそれがあります ハンドル ...

Страница 40: ...項 確認 3 5 インチストレージベイの奥まで完全に差し込まれていますか すべての内蔵ハードディスクが取り付けられていますか 確認事項 確認 指示どおりに接続されていますか 各ドライブのコネクタに完全に差し込まれていますか すべてのケーブルが取り付けられていますか 取り外すように指示してあるケーブルは取り外しましたか 1 変換作業前の準備 でサーバ本体から取り外した電源ケーブルは接 続しましたか 確認事項 確認 拡張カードがスロットの奥まで完全に差し込まれていますか 変換作業時の衝撃でカードの差し込みがゆるむ場合があります 確認事項 確認 1 変換作業前の準備 で取り外した周辺機器は 元どおりに正しく接 続しましたか ...

Страница 41: ...A WRTID BAT C200R ini Enter 正常に行なわれると 以下のように表示されます Normal END 6 サーバ本体の電源を切ります 警告 ServerStart CD またはリカバリ CD やハードウェア構成ツール 起動用フロッピーディスクを入れてシステムを起動する前に ServerView の OS ブート監視 機能が無効に設定されている ことを確認してください 初期設定は無効です OS ブート監視 機能を有効にしたままでシステムを起動する と 本サーバが自動的に電源切断や再起動するなど 意図しな い動作をするおそれがあります OS ブート監視 機能を有効にして運用している場合は 運用 を再開する前に 再度本機能を有効にしてください ServerView の詳細については ServerView の CD ROM 内の ServerView ユーザーズガイド を参照...

Страница 42: ...確認しま す 2 ディスプレイや周辺装置の電源スイッチを押しま す 3 サーバ本体に添付の ハードウェア構成ツール起動 用フロッピーディスク ディスクをセットし サー バを起動します 4 Menu より Server Management Tool を選択し Enter キーを押します DOS プロンプトが表示されたら フロッピィディスクを 取り出します 5 サーバ本体に添付の Server Management Tools ディスクをフロッピィディスクドライブにセット し 次のコマンドを入力します A WRTID BAT C200F ini Enter 正常に行なわれると 以下のように表示されます Normal END 6 サーバ本体の電源を切ります ...

Страница 43: ...32 操作方法 ...

Страница 44: ...よびラックマウント変換機構型名を記 録します この使用環境シートは担当営業員または担当保守員への連絡時に必要となりますの で なくさないようにご注意ください サーバ ラック型名 PRIMERGY モデル名 型名 シリアル番号 Product Key ラックマウント変換機構型名 GP PG サーバ本体の左右どちらかの側面にProduct Keyラベルが貼付されて いる場合にのみ記載してください C200 FileServerエントリモデル PG R1CK7 PG R1CK10 ...

Страница 45: ...34 付録 ...

Страница 46: ... Kit PG R1CK7 This rack conversion kit enables you to convert your server from a deskside model to a rack mount model This manual explains how to implement the PRIMERGY C200 Rack Conversion Kit Please review the information outlined in this manual when using the PRIMERGY C200 Rack Conversion Kit March 2002 ...

Страница 47: ... rack type Standard type rack cabinet PG R3RC1 PG R3RC2 PG R4RC1 PG R4RC2 Slim type rack cabinet GP5 R1RC6 GP5 R1RC7 GP5 R2RC3 GP5 R2RC4 All hardware and software names used are trademarks of their respective manufactures All Rights Reserved Copyright FUJITSU LIMITED 2002 Standard type rack cabinet Slim type rack cabinet ...

Страница 48: ...nstructions under this symbol when using the server could be hazardous as well as lethal Ignoring the instructions under this symbol when using the server may lead to injuries as well as damage the server or hard ware options The triangle mark emphasizes the urgency of the WARN ING and CAUTION contents Inside the triangle and above it are details concerning its symbol e g Electrical Shock This mar...

Страница 49: ... the connecting cables in a way that they become trip hazards This could damage the server and cause injury Do not use the server in a salty environment Do not obstruct the ventilation slots This could cause over heating and shorten the life of the equipment Do not string the connecting cables in a way that they become trip hazards This could both damage the server and cause injury Do not place th...

Страница 50: ...way diskcopy a a The indicates to press the Space key once The commands are not case sensitive Expressions and abbreviations The following are expressions and abbreviations used thoughout this manual Rack Conversion Kit this product Refers to PRIMERGY C200 Rack Conversion Kit the server this server Refers to PRIMERGY C200 This server is available in the following models Deskside model Rackmount mo...

Страница 51: ...vi ...

Страница 52: ...cover 13 7 Removing the right side cover 14 8 Remove the rubber feet 15 9 Repositioning the devices 17 10 Attaching the front cover brackets 19 11 Reattaching the front cover 20 12 Reattaching the left side cover 20 13 Attaching the rack front cover 21 14 Converting to a rackmount model 21 15 Reinstalling the hard disk units 29 16 Before turning on the server 30 17 Updating the Chassis ID 31 Appen...

Страница 53: ...viii ...

Страница 54: ...ure that all of the following items are included in the rack conversion kit If any items are missing inform your Fujitsu sales representative Item Name Qty Check Rack front cover 1 Rail bracket 2 Rack rail 2 Front cover bracket 2 ...

Страница 55: ...2 Ensuring the package Bracket A 1 1 pair Bracket B 1 2 Bracket C 1 2 M4 binding head screw 14 M4 tap tight screw 8 M5 screw 1 8 Item Name Qty Check Left Right ...

Страница 56: ...3 E 1 Only necessary for a slim type rack cabinet 2 Only necessary for a standard type rack cabinet M6 screw 1 4 M6 flathead screw 1 4 Washer 1 4 M5 rack nut 4 Spring nut 2 4 Item Name Qty Check ...

Страница 57: ...4 Ensuring the package ...

Страница 58: ...n a sta ble and level surface when perform the conversion work as the combined weight can be in excess of 30kg Also work in an open space as the rackmount must be laid horizontally to perform the conversion Make sure that the system is operating properly before per forming the conversion Devices inside the server remain hot after shutdown Wait for approximately 10 minutes after shutdown before ins...

Страница 59: ...er 7 Remove the right side cover 8 Remove the rubber feet 9 Reorient the devices 10 Attach the front cover brackets 11 Reattach the front cover 12 Reattach the left side cover 13 Attach the rack front cover 14 Converting to a rackmount 15 Reinstall the hard disk units 16 Before turning on the server 17 Update the Chassis ID Before moving the server remove all hard disk units Striking or hitting a ...

Страница 60: ...play and any attached peripherals 4 Disconnect all peripherals and unplug all device power cords 2 Removing the hard disk cover 1 Turn the drive cover key counterclockwise to unlock the server Wear a wrist grounding strap before removing and attaching covers Be careful not to lose this key If you lose the drive cover key contact your maintenance engi neer immediately Drive cover key ...

Страница 61: ...over to the upward position pull the underlying hard disk cover forward to remove 4 Wear a wrist grounding strap A suitable wrist grounding strap has a side that connects to the server A and a side to tie around the wrist B Remove the seal side A and affix it to the server Drive cover A B Wrist grounding strap ...

Страница 62: ... different The following diagram shows the bay numbers and SCSI IDs before and after con version Make sure to write down the bay numbers and SCSI IDs for each hard disk so they can be replaced to their proper loca tions Before moving the server remove all hard disk units Striking or hitting a hard disk unit can corrupt its data Bay 2 ID 5 Bay 1 CD ROM DVD ROM Deskside model s front FDD Bay 4 ID 3 ...

Страница 63: ...its Pressing the release button A on the hard disk unit raise the handle upward to release the lock and pull out to remove 4 Removing the drive cover 1 Lower the drive cover Slowly lower the drive cover down and return it to its original position A B Handle Drive cover ...

Страница 64: ...ver 11 E 2 Open the drive cover Pull the drive cover forward while pressing the upper latches on both sides see diagram 3 Remove the drive cover Pull the drive cover in the direction as shown in the diagram to remove Latches ...

Страница 65: ...cated at the rear 2 Slide the left side cover The side cover is fastened to the chassis by tabs Carefully slide the left side cover toward the rear as shown in the diagram to release the tabs from the chassis and remove Do not lose these screws since they will be used later to reat tach this cover ...

Страница 66: ...se the 3 tabs on the left side of the front cover then pull the cover off while pressing the 2 tabs on the right side 2 Remove the 3 retaining screws M3 located on the inside of the front cover and detach the drive cover stopper from the front cover Left tabs Right tabs Drive cover stopper ...

Страница 67: ...oving the right side cover 1 Remove the 2 retaining thumbscrews M3 located at the rear 2 Release the upper tab Insert a flathead screwdriver in the opening on the left side this cover is L shaped and pry open to release the tab Tab ...

Страница 68: ...rds Slide the L shaped right side cover backwards while applying downward pressure on the cover s top 8 Remove the rubber feet 1 Lay the server on its side see diagram 2 Remove the 2 upper rubber feet Pull off the 2 rubber feet bumpers by hand from the server s base ...

Страница 69: ...16 Conversion procedure 3 Remove the 3 retaining screws M4 fixing the lower plate 4 Slide the plate toward the rear as shown in the diagram and remove ...

Страница 70: ...l 5 inch internal devices all blank units Operator panel See the following diagram to identify their new orientation 1 Disconnect all cable connections from the CD ROM DVD ROM drive and 5 inch internal devices 2 Separate only the operator panel cables from the bundle CD ROM or DVD ROM drive Before After Operator panel 5 inch internal devices or blank units Inside of the server Cable tie ...

Страница 71: ...t of its bay see diagram 4 Orient the operator panel CD ROM DVD ROM drive all 5 inch internal devices and or blank units into their 5 inch bays POINT Depending on the number of devices installed there may not be any blank units When installing these components be careful not to pinch the cables between the other components POINT Depending on the number of devices installed there may not be any bla...

Страница 72: ...step 1 7 Re tie the operator panel cables separated in step 2 10 Attaching the front cover brackets 1 Attach the front cover brackets on the right and left side of the server Fasten each bracket to the side of the server with the 2 tap tight screws M4 provided Intrusion cable Left side of the server Screw holes ...

Страница 73: ...ront cover to secure into place 12 Reattaching the left side cover Perform the removal procedure in reverse to reattach the left side cover to the server Refer to 5 Removing the left side cover 12 page for details Upper tabs Lower tabs Remain wearing the wrist grounding strap until the side cover is completely attached Before replacing the left side cover check to see whether any tools were left i...

Страница 74: ...ed 14 Converting to a rackmount model Perform the following steps to implement the rack conversion kit and install the server in the rack For details on attaching the slide rails refer to your rack type instructions Attaching the inner rail 1 Separate the inner rails from the slide rail Holding the lock pressed see diagram slowly pull the inner rail outward to remove Slide rail Inner rail Lock ...

Страница 75: ...ock is fac ing the front of the server see dia gram 3 Attach the slide rail unit to the rail brackets Fasten each slide rail unit to its respective rail bracket with the 4 binding head screws M4 provided It may be necessary to slightly shift the rail and bracket when tightening the screws see diagram Inner rail M4 binding head screw Direction of lock Server front Rail bracket Slide rail Fasten the...

Страница 76: ...server in the rack by aligning the base of the server to match to any narrow space in the rack support Installing the rails assembly For a standard type rack cabinet 1 Attach the spring nuts to the rack Insert the spring nuts into the rack grooves as shown in Fig 1 4 below The height of the spring nuts can be adjusted once placed inside the rack groove by sliding each nut up or down by hand Fig 5 ...

Страница 77: ...nsert the rack nuts provided Insert the rack nuts in the rack s 3rd and 13th hole positions counting from the bracket s base as shown in the diagram Make sure to use the rack nuts provided with the kit M5 as they have special catches to secure their hole positions Make sure to use the rack nuts M5 provided with the rack con version kit and not the ones used on the rack cabinet M5 screws Front To 3...

Страница 78: ...s using the screws M5 provided Attach brackets A and B to the inner side of the rails and fasten Attach the C brackets to the rear of the rails and LOOSELY tighten to allow its length to be adjusted in the next step Bracket A Slide rail M5 screws Left Right Bracket A Bracket B Bracket B Bracket C Bracket C Slide rail M5 screws M5 screws Front Rear Latch Latch ...

Страница 79: ...26 Conversion procedure 2 Extend each rail to align with the rack cabinet width and tighten the rear screws from above to fix the length of the rails Left of rack cabinet Frame Front Rear ...

Страница 80: ...n a similar way except using the screws M6 and washers provided in this kit instead of the flathead screws 2 Attach the rack nuts provided Insert the rack nuts in the 3rd and 13th hole positions counting from the bot tom as shown in the diagram When inserting the nuts make sure to use the ones provided with the kit M5 as they have special catches to secure their hole positions Make sure to use the...

Страница 81: ...ver in the rack 1 Fully extend the slide rails 2 Properly seat the server into rail grooves of the rail assembly 3 Install the server in the rack cabinet Holding the lock on the slide rail pressed push the server into the rack cabinet Lock Lock ...

Страница 82: ...nits to the server With its handle open insert each hard disk unit back into their respective 3 5 inch storage bays Close the handle to lock the hard disk units in their storage bays Be careful not to pinch your fingers or catch any clothing when sliding the server into the cabinet Be sure to reinstall the hard disk units back to their correct bays from which they were removed Handle ...

Страница 83: ...tem Check Are all cable connections correct Is each cable properly seated Are all cables connected Did you disconnect the cables as instructed Did you reconnect the server s power cable from 1 Pre work preparations Item Check Are all expansion cards properly seated in their PCI slots Some expansion cards may have become loose while performing the conversion Item Check Did you reconnect the periphe...

Страница 84: ...following commands A WRTID BAT C200R ini Enter The following message appears when properly executed Normal End 6 Turn off the server Before rebooting the system from the ServerStart CD or Hard ware Configuration Tool Floppy first check that the ServerView OS Boot Monitoring function has been disabled default setting is Disabled If the system is started with the OS Boot Monitoring function enabled ...

Страница 85: ...ion Tool Boot Floppy provided with the server in the floppy disk drive and turn on the server The menu will appear 4 Select Server Management Tool from menu and press Enter After appearing the DOS prompt remove the Hardware Config uration Tool Boot Floppy 5 Insert the Server Management Tools disk provided with the server into the floppy disk drive and type the following commands A WRTID BAT C200F ...

Страница 86: ...this sheet as you must provide this information when you contact your maintenance engineer Server Rack Model PRIMERGY C200 Name Product ID Serial number Product Key Rack Conversion Kit Type GP PG PG R1CK7 Record the product key if there is a product key label affixed on either side of the server ...

Страница 87: ...34 ...

Страница 88: ... to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written per mission of Fujitsu PRIMERGY C200 FileServer ラックマウント変換機構 PG R1CK7 PG R1CK10 取扱説明書 PRIMERGY C200 Rack Conversion Kit PG R1CK7 USER GUIDE P3FY 2170 01 00 発行日 2002 年 3 月 発行責任 富士通株式会社 Issued on March 2002 Issued by FUJITSU L...

Страница 89: ...このマニュアルは再生紙を使用しています PRIMERGY P3FY 2150 01 E J マニュア 製品名称 PRIMERGY F200 ラックマウント変換機構 PG R1CK6 PRIMERGY F200 Rack Conversion Kit PG R1CK6 J E ...