BX922 S2
Options Guide
29
Processors
Installing the heat sink
Ê
Carefully remove the heat sink from the packaging. Take care
not to touch the thermal paste on the underside of the heat sink.
Figure 10: Securing the heat sink for CPU 2
Ê
Carefully place the heat sink on the CPU.
Ê
Fasten the heat sink in place by tightening the four pre-mounted screws (see
circles) in a crossover pattern.
V
CAUTION!
Never install a processor without a heat sink as otherwise the
processor may overheat, causing the possible failure of the
processor and system board.
Ê
Close the server blade, re-insert it in the system unit and switch it on as
described in
chapter "Completion" on page 67
and following.