BX920 S4
Upgrade and Maintenance Manual
79
Basic software procedures
iRMC recovery procedue
The iRMC recovery is performed via the
FlashDisk
menu executed from a
bootable USB memory stick. For detailed information refer to the "Integrated
Remote Management Controller" user guides available online.
I
For the Japanese market, follow the instructions provided separately.
Ê
Shut down the server blade as described in section
Ê
Connect the monitor, keyboard, mouse and the bootable USB memory stick
to the port on the front of the server blade using the Y cable, see the
Operating Manual.
Ê
Switch on the server blade while as described in section
to boot from the USB memory stick.
After completion of the boot operation, the
FlashDisk
menu opens.
Ê
Select
Recovery _L
to carry out the recovery flash for firmware image 1 (low
firmware image).
Ê
Select
Recovery _U
to carry out the recovery flash for firmware image 2 (high
firmware image).
Ê
Once the update operation has been completed, click on
Exit
, to close the
FlashDisk
menu.
Ê
Shut down the server blade as described in section
Ê
Remove the Y-cable.
Ê
Switch on the server blade as described in section
Ê
You can now put the server blade back into operation.