BX400 S1
Operating Manual
109
Hot-plug components
Port assignment
Each of the 8 server blades of a BX400 S1 system unit can be equipped with 2
FC mezzanine cards each with 2 ports (0, 1). Each of the server blade FC ports
is connected to a dedicated port of an FC pass thru connection blade in a
defined connection blade slot. The table below shows the port assignment of
mezzanine card ports and connection blade slots.
The FC pass thru port numbers are related to the server blade slot numbers.
Example
Mezzanine card 1 port 0 of server blade in slot 6 is connected to port 6 of FC
pass thru connection blade in slot 2 (CB2).
Port 0 of mezzanine card 1 is connected to port 7 of FC pass thru connection
blade in slot 3.
For information about port assignment of mezzanine cards and connection
blade slots please refer also to
"Fitting rules for connection blades" on page 120
and
"Port assignment of the connection blades" on page 123
Mezzanine card 1
Mezzanine card 2
Server blade slot
Port 0
Port 1
Port 0
Port 1
1
CB2 port 1
CB2 port 9
CB3 port 1
CB4 port 1
2
CB2 port 2
CB2 port 10
CB3 port 2
CB4 port 2
3
CB2 port 3
CB2 port 11
CB3 port 3
CB4 port 3
4
CB2 port 4
CB2 port 12
CB3 port 4
CB4 port 4
5
CB2 port 5
CB2 port 13
CB3 port 5
CB4 port 5
6
CB2 port 6
CB2 port 14
CB3 port 6
CB4 port 6
7
CB2 port 7
CB2 port 15
CB3 port 7
CB4 port 7
8
CB2 port 8
CB2 port 16
CB3 port 8
CB4 port 8