![Fujitsu PRIMEQUEST 2800B3 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/fujitsu/primequest-2800b3/primequest-2800b3_system-configuration-manual_120971013.webp)
System Configuration Guide
PRIMEQUEST 2800B3
Disk Unit
MC-5HDU21B / MCX5HDU21B (LD)
- Max. 2 x Disk Unit per Base Unit
- Min. 1 x RAID Controller cards per Disk Unit needs to be mounted.
- Max. 2 x RAID Controller cards per Disk Unit can be mounted.
- Max. 4 x HDD/SSD can be mounted in case 1 x RAID Controller card is
mounted.
- Max. 2 x HDD/SSD can be mounted per RAID Controller card in case
2 x RAID Controller cards are mounted.
SAS RAID Controller Card
MC-0JSR51 / MCX0JSR51 (LD)
- 1 x RAID Controller can connect max. 4 x disk drives such as
HDD and SSD.
- 1 x Flash Backup Unit can be mounted.
- Data transfer speed: SAS 12Gbps. Cache memory: 2GB
- RAID 0/1/1E/5/6/10 and hot spare supported
RAID Advanced Software Options
MC-0KLA31 / MCX0KLA31 (LD)
- License Activation Key for MegaRAID
CacheCade 2.0
Flash Back-up Unit
MC-0JFB31 / MCX0JFB31 (LD)
- Flash Backup Unit for RAID Controller
with cache memory
Internal HDD in Disk Unit
7. Disk Unit
I/O Unit #0
PCI Slot
LAN port
I/O Unit #2
PCI Slot
LAN port
I/O Unit #1
PCISlots
LAN Port
I/O Unit #3
PCI Slot
LAN Port
Disk Unit #0
HDD
RAID
Card
Disk Unit #1
HDD
RAID
Card
SB #2
CPU
CPU
Memory
Memory
SB #1
CPU
CPU
SB #3
CPU
CPU
Memory
Memory
Memory
Memory
SB #0
CPU
CPU
Memory
Memory
RAID
Card
RAID
Card
MMB #0
PSU/
FAN #0
PSU/
FAN #1
PSU/
FAN #2
PSU/
FAN #3
PSU/
FAN #4
PSU/
FAN #5
FUJITSU Server PRIMEQUEST
13 / 28