6.4.3
Installing the PSHED Plugin driver
The PSHED Plugin driver expands the WHEA (Windows Hardware Error Architecture) functions.
This driver is not automatically installed. Manually install the driver with the batch file (plugin_install.bat) stored
in the following folder.
PSA installation folder
\fjpsaplg\plugin_install.bat
(Example: C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg\plugin_install.bat)
Remarks
The following functions do not work unless the driver is installed:
- Suppression of logging of Correctable Error events to the Event Viewer (Windows system event log)
- State transition to Stop Error for a Blue Screen of Death event ([System Progress] in the [Power Control]
window of the MMB Web-UI)
Notes
- Do not execute the installation batch more than once.
If it is executed more than once, as many PRIMEQUEST PSHED Plugin drivers as the number of times
executed are installed.
- If the installation batch is executed multiple times, no operational problems occur but multiple
PRIMEQUEST PSHED Plugin drivers are displayed by the Device Manager.
In this case, uninstall all the PRIMEQUEST PSHED Plugin drivers and then reinstall one according to the
following procedure. After the reinstallation, the operating system must be restarted.
1. Record the number of times [PRIMEQUEST PSHED Plugin Driver] appears under [System Devices]
in the Device Manager.
2. Execute the following PSHED Plugin driver uninstallation batch as many times as the number recorded
in step 1.
PSHED Plugin driver uninstallation batch storage location:
PSA uninstallation folder
\fjpsaplg\plugin_uninstall.bat
(Default. C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg
\plugin_uninstall.bat)
3. Restart the operating system.
4. Confirm that no [PRIMEQUEST PSHED Plugin Driver] appears under [System Devices] in the Device
Manager.
5. Reinstall the PRIMEQUEST PSHED Plugin driver according to
below.
Operations
1. Open the following folder, and double-click [plugin_install.bat].
PSA installation folder
\fjpsaplg
(Example: C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg)
2. Restart the operating system. Then, the driver starts running.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
166
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......