8. Replace the media with the operating system installation media according to the SVIM instructions.
4.8.4
Configuring a software watchdog
1. Start ServerView Operations Manager.
2. Select [ServerList].
3. Right-click the target partition in the server list on the left side. Select [Maintenance] - [ASR Properties] from
the displayed menu.
4. Select [Watchdog] in the displayed window.
5. Specify the following for [Software], and click [Apply].
- Check the [Active] check box.
- Select [Continue] for [Action] for cases of abnormal operation.
- Enter a value between 1 and 100 minutes for [Timeout].
6. Enter your user name and password, and press the [Enter] key.
4.8.5
Completing VMware 5.x installation
After completing the settings, reboot the partition of the PRIMEQUEST 1000 series server.
4.8.6
Installing bundled software
For bundled software installation, see
E.7 Installing VMware 5.x Bundled Software
.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 4 Installing the Operating System and Bundled Software
100
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......