Interface
5-68
C141-E293
Table 5.20 SMART self-test log data format
Byte(hex) Item
00, 01
Self-test log data structure
02
Self-test number (Sector Number field Value)
03
Self-test execution status
04, 05
Life time. Total power-on time [hours]
06
Self-test error No.
07 to 0A
Error LBA
0B to 19
Self-test log 1
Vendor unique
1A to 1F9
Self-test log 2 to 21
(Each log data format is the same as that in
byte 02 to 19.)
1FA, 1FB
Vendor unique
1FC Self-test
index
1FD, 1FE
Reserved
1FF Check
sum
•
Self-test number
Indicates the type of self-test executed.
•
Self-test execution status
Same as byte 16Bh of the attribute value.
•
Self-test index
If this is "00h", it indicates the status where the self-test has never been executed.
•
Checksum
Two's complement of the lower byte, obtained by adding 511-byte data one byte at a
time from the beginning.
Содержание MJA2080BH
Страница 4: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 44: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 253: ...5 4 Command Protocol C141 E293 5 179 Device Host RegHD PIO Setup DATA Figure 5 14 PIO data in command protocol ...
Страница 284: ...This page is intentionally left blank ...
Страница 300: ...This page is intentionally left blank ...
Страница 304: ...This page is intentionally left blank ...
Страница 306: ...This page is intentionally left blank ...
Страница 314: ...This page is intentionally left blank ...
Страница 316: ...This page is intentionally left blank ...
Страница 318: ......
Страница 319: ......
Страница 320: ...Back Cover ...