Interface
5-18
C141-E070-01EN
Command block registers contain the cylinder, the head, and the sector addresses
of the sector (in the CHS mode) or the logical block address (in the LBA mode)
where the error occurred, and remaining number of sectors of which data was not
transferred.
At command issuance (I/O registers setting contents)
1F7
H
(CM)
0
0
1
0
0
0
0
R
1F6
H
(DH)
×
L
×
DV
Start head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
R = 0
→
with Retry
R = 1
→
without Retry
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
L
×
DV
End head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No. / LBA [LSB]
00 (*1)
Error information
*1
If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(2) READ MULTIPLE (X’C4’)
This command operates similarly to the READ SECTOR(S) command. The
device does not generate an interrupt (assertion of the INTRQ signal) on each
every sector. An interrupt is generateed after the transfer of a block of sectors for
which the number is specified by the SET MULTIPLE MODE command.
Содержание MHG2102AT - Mobile 10 GB Hard Drive
Страница 1: ...C141 E070 02EN MHG2102AT MHH2064AT MHH2048AT MHH2032AT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 5: ...This page is intentionally left blank ...
Страница 9: ...This page is intentionally left blank ...
Страница 11: ...This page is intentionally left blank ...
Страница 13: ...This page is intentionally left blank ...
Страница 37: ...This page is intentionally left blank ...
Страница 40: ...3 1 Dimensions C141 E070 01EN 3 3 Figure 3 1 Dimensions MHH series 2 2 ...
Страница 51: ...Installation Conditions 3 14 C141 E070 02EN Figure 3 15 Example 2 of Cable Select ...
Страница 56: ...4 3 Circuit Configuration C141 E070 01EN 4 5 Figure 4 2 Circuit Configuration 16 bit ...
Страница 62: ...4 6 Read write Circuit C141 E070 01EN 4 11 Figure 4 4 Read write circuit block diagram ...
Страница 73: ...This page is intentionally left blank ...
Страница 169: ...Interface 5 96 C141 E070 01EN Figure 5 10 Data transfer timing ...
Страница 185: ...This page is intentionally left blank ...
Страница 188: ...6 1 Device Response to the Reset C141 E070 01EN 6 3 Figure 6 1 Response to power on 31 sec 30 sec ...
Страница 209: ...This page is intentionally left blank ...
Страница 213: ...This page is intentinally left blank ...
Страница 215: ...This page is intentionally left blank ...
Страница 220: ...This page is intentinally left blank ...
Страница 223: ......