4.5 ATA Commands
C156-E227-01EN
4-35
Table 4.27 Error register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
WRT_PT
MC
0
MCR
0
NOMED
0
WRT_PT: Set to 1 when write-protected.
MC: Set to 1 when media is exchanged. Reported only once.
MCR: Set to 1 when the Eject switch is pressed. Reported only once.
NOMED: Set to 1 when no media is inserted.
If this command is received while the media status notification function is
disabled, this command responds with the ODD status assuming that the media
status notification function is enabled. Subsequently, this command operates
assuming that the media status notification function is enabled until it is set to
disabled.
4.5.7 IDLE IMMEDIATE (95h/E1h)
Table 4.28 IDLE IMMEDIATE command
Bit
7
6
5
4
3
2
1
0
1
0
0
1
0
1
0
1
CM
1
1
1
0
0
0
0
1
DH
X
X
X
DRV
X
X
X
X
CH
X
X
X
X
X
X
X
X
CL
X
X
X
X
X
X
X
X
SN
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
FR
X
X
X
X
X
X
X
X
The ODD sets the power mode to idle mode.
Содержание MCM3064AP
Страница 1: ...C156 E227 01EN MCM3064AP MCM3130AP OPTICAL DISK DRIVES PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 32: ...This page is intentionally left blank ...
Страница 50: ...Installation Requirements 3 6 C156 E227 01EN Figure 3 3 Outer dimensions 1 3 ...
Страница 52: ...Installation Requirements 3 8 C156 E227 01EN Figure 3 3 Outer dimensions 3 3 ...
Страница 190: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 200: ...This page is intentionally left blank ...
Страница 201: ......
Страница 202: ......