4.2 Power Supply Requirements
Figure 4.7 shows the Max Seek current waveform of +5V DC and +12V DC.
+5VDC
+12VDC
MBB2147RC
MBB2147RC
MBB2073RC
MBB2073RC
Cur
rent
(500m
A/
div)
Cur
rent
(500m
A/
div)
Cur
rent
(500m
A/
div)
Cur
rent
(500m
A/
div)
Time(2 sec/div)
Time(2 sec/div)
Time(2 sec/div)
Time(2 sec/div)
Figure 4.7 Current waveform (Max seek)
(3)
Power on/off sequence
The order of the power on/off sequence of +5V DC and +12V DC, supplied to the HDDs, does not
matter.
(4)
Sequential starting of spindle motors
After power is turned on to the HDDs, a large amount of current flows in the +12V DC line when the
spindle motor rotation starts. Therefore, if more than one HDDs are the spindle motors should be
started sequentially using one of the following procedures to prevent overload of the power supply
unit.
a) Control the sending of the NOTIFY (ENABLE SPINUP) primitive so that the spindle motors of
individual HDDs are started in intervals of 12 seconds or more.
b) Turn on the +12V DC power in the power supply unit at intervals of 12 seconds or more to start
the spindle motors sequentially.
C141-E257
47
Содержание MBB2073RC SERIES
Страница 1: ...C141 E257 02EN MBB2147RC MBB2073RC HARD DISK DRIVES PRODUCT MANUAL ...
Страница 10: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 24: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 82: ...Diagnostics and Maintenance 78 C141 E257 Figure 6 4 Fraction packaging ...
Страница 88: ...This page is intentionally left blank ...
Страница 94: ...This page is intentionally left blank ...
Страница 96: ...This page is intentionally left blank ...
Страница 97: ......
Страница 98: ......