C141-E134-01EN
5 - 11
4) When an electric driver is in use, less than device specifications must be used.
5.5
Connecting Cables
Connect the IDD and system with the following cables. See Section 4.3 for further details of the
requirements for IDD connector positions and connecting cables.
•
Power cable
•
SCSI cable
•
External operator panel cable (if required for MP model)
The general procedures and notes on connecting cables are described below. Especially, pay
attention to the inserting orientation of each cable connector.
CAUTION
Damage
1.
Make sure that system power is off before connecting or disconnecting
cables.
2.
Do not connect or disconnect cables when power is on. (except MC
model)
a) Connect power cable.
b) Connect the external operator panel (if required for MP model).
c) Connect the SCSI cable.
d) Fix the cables so that they do not touch the DE and PCAs, or so that the smooth flow of the
cooling air in the system cabinet is assured.
CAUTION
Damage
1.
Be careful of the insertion orientations of the SCSI connectors. With the
system in which terminating resistor power is supplied via the SCSI
cable, if the power is turned on, the overcurrent protection fuse of the
terminating resistor power supplier may be blown or the cable may be
burnt if overcurrent protection is not provided.
When the recommended parts listed in Table 4.2 are used, inserting the
cables in the wrong orientation can be prevented.
2.
To connect SCSI devices, be careful of the connection position of the
cable. Check that the SCSI device with the terminating resistor is the last
device connected to the cable.
Содержание MAM3184MC
Страница 1: ...C141 E134 01EN MAM3367MC MP SERIES MAM3184MC MP SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 18: ...This page is intentionally left blank ...
Страница 28: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 66: ...C141 E134 01EN 4 14 Figure 4 17 External operator panel connector CN2 ...
Страница 88: ...C141 E134 01EN 5 14 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A 60 ...
Страница 124: ...8 8 C141 E134 01EN Figure 8 3 Block diagram of read write circuit ...
Страница 130: ...This page is intentionally left blank ...
Страница 134: ...This page is intentionally left blank ...
Страница 140: ...This page is intentionally left blank ...
Страница 148: ...This page is intentionally left blank ...
Страница 150: ...This page is intentionally left blank ...
Страница 151: ......
Страница 152: ......