C141-E078-02EN
6 - 4
When an error is detected in the self-diagnostics, the IDD terminates the SEND
DIAGNOSTIC command with the CHECK CONDITION status. If an error is detected by a
hardware function test at this time, the Fault LED lights up.
The INIT should issue the REQUEST SENSE command when the CHECK CONDITION
status is posted. The sense data collected by the REQUEST SENSE command indicates the
detail information of the error detected in the self-diagnostics.
The IDD status after the CHECK CONDITION status is posted differs according to the type
of the detected error.
a)
When an error is detected in the seek or write/read test, the subsequent command can be
accepted correctly. When the command other than the REQUEST SENSE and NO
OPERATION is issued from the same INIT, the error information (sense data) is
cleared.
b)
When an error is detected in the hardware function test, the IDD posts the CHECK
CONDITION status for all I/O operation request except the REQUEST SENSE
command. The error status is not cleared and the Fault LED continues lighting up even
if the error information (sense data) is read. Only when the SCSI bus is reset, the BUS
DEVICE RESET message is issued or the power is turned off or re-turned on, the status
can be cleared. When this status is cleared, the IDD executes the initial self-diagnostics
again (see item (1)).
Refer to Chapter 4 of Fibre Channel Interface Specifications for further details of the
command specifications.
CAUTION
Data loss
When the SEND DIAGNOSTIC command terminates with the
CHECK CONDITION status, the INIT must collect the error
information using the REQUEST SENSE command. The RECEIVE
DIAGNOSTIC RESULTS command cannot read out the error
information detected in the self-diagnostics.
6.1.2
Test programs
The basic operations of the IDD itself can be checked with the self-diagnostic function. However,
to check general operations such as the host system and interface operations in a status similar to
the normal operation status, a test program that runs on the host system must be used.
The structure and functions of the test program depend on the user system requirements.
Generally, it is recommended to provide a general input/output test program that includes devices
connected to the loop and input/output devices on other I/O ports.
Including the following test items in the test program is recommended to test the IDD functions
generally.
Содержание MAF3364FC SERIES
Страница 3: ...This page is intentionally left blank ...
Страница 14: ...C141 E078 02EN xiii Glossary GL 1 Abbreviations AB 1 ...
Страница 17: ...This page is intentionally left blank ...
Страница 47: ...This page is intentionally left blank ...
Страница 49: ...C141 E078 02EN 4 2 Figure 4 1 External dimensions MAF3364FC ...
Страница 50: ...C141 E078 02EN 4 3 Figure 4 2 External dimensions MAG series ...
Страница 66: ...C141 E078 02N 5 7 Motor starts when power is turned on Figure 5 1 Checking the IDD connection A For Figure 5 2 ...
Страница 75: ...This page is intentionally left blank ...
Страница 99: ...This page is intentionally left blank ...
Страница 104: ...This page is intentionally left blank ...
Страница 107: ......