TIMER OPERATION

s

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (

 P. 4).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 

S

)

(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Press the TIMER MODE button (Fig. 6 

P

) to select the

OFF timer or ON timer operation.

Each time the button is pressed the timer function changes in the follow-
ing order:

       CANCEL

OFF

ON

PROGRAM(OFF 

 ON, OFF 

 ON)

The indoor unit’s green TIMER Indicator Lamp (Fig. 3 

6

) will light.

3

Use the TIMER SET buttons (Fig. 6 

Q

) to adjust the

desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue
for about five seconds).

 button:

Press to advance the time.

 button:

Press to reverse the time.

About five seconds later, the entire display will reappear.

To Use the Program timer

1

Press the START/STOP button (Fig. 6 

S

).

(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired
mode and times.
About three seconds later, the entire display will reappear.
The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 

6

) will light.

3

Press the TIMER MODE button (Fig. 6 

P

) to select the

PROGRAM timer operation (OFF   ON or OFF   ON
will display).

The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.

The program timer will begin operation. (If the ON timer has been se-
lected to operate first, the unit will stop operating at this point.)

About five seconds later, the entire display will reappear.

About the Program timer

The program timer allows you to integrate OFF timer and ON timer operations in
a single sequence. The sequence can involve one transition from OFF timer to
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Control Unit’s
Display (OFF 

 ON, or OFF 

 ON).

One example of Program timer use might be to have the air conditioner auto-
matically stop (OFF timer) after you go to sleep, then start (ON timer) automati-
cally in the morning before you arise.

To Cancel the Timer

Use the TIMER button to select “CANCEL”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the
timer setting wait until the entire display
reappears, then press the appropriate
buttons to change the operating condition
desired.

s

s

t

To Cancel the Timer

Use the TIMER MODE button to select
“CANCEL”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

1. Follow the instructions given in the section

“To Use the ON Timer or OFF Timer” to se-
lect the timer setting you wish to change.

2. Press the TIMER MODE button to select

either OFF 

 ON or OFF 

 ON.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the timer
setting wait until the entire display reap-
pears, then press the appropriate buttons to
change the operating condition desired.

Содержание Inverter Halcyon AOU24RLXQ

Страница 1: ......

Страница 2: ......

Страница 3: ...TÉRIEURE ASU24RLXQ AOU24RLXQ HEAT COOL MODEL MODÈLE RÉVERSIBLE MODELO DE REFRIGERACIÓN Y CAlEFACCÓN ICACIONES N 208 230 V 60 Hz N D 30600 BTU h DE ALIMENTACIÓN 3 86 kW 17 0 A D 32000 BTU h DE ALIMENTACIÓN 3 00 kW 13 2 A ECHNIQUE 208 230 V 60 Hz ENT E FRIGORIFIQUE 30600 BTU h E ABSORBÉE 3 86 kW 17 0 A E FRIGORIFIQUE 32000 BTU h E ABSORBÉE 3 00 kW 13 2 A CATIONS Y 208 230 V 60 Hz 30600 BTU h WER 3 8...

Страница 4: ......

Страница 5: ...ration HORIZONTAL AIRFLOW COOLING DOWNWARD AIRFLOW HEATING For cooling use horizontal airflow so the cool air does not blow directly on the occupants in the room For heating use downward airflow to send powerful warm air to the floor and create a comfortable environment OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of bot...

Страница 6: ...Fan Speed Display b Temperature SET Display c AIR CLEAN Display d COIL DRY Display e SLEEP Display f SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time...

Страница 7: ...e direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 Y Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 Q to adjust the clock to the current time button Press to advance the time bu...

Страница 8: ...TROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperat...

Страница 9: ...ut 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defros...

Страница 10: ...he operation install the intake filter and then use the START STOP button to restart the operation Use the FAN CONTROL button to change the fan speed Refer to page 5 The plasma filter unit operates most effectively at the highest fan speed The AIR CLEAN Indicator Lamp orange will flash to inform you that the periodic cleaning of the plasma filter unit is required Refer to page 13 14 AIR CLEANING O...

Страница 11: ...econds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operat...

Страница 12: ...ps During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the ...

Страница 13: ...cally return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 T Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Co...

Страница 14: ...ot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direc tion Airflow dir...

Страница 15: ...ille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and ...

Страница 16: ...4 to 113 F for 10 to 15 minutes If the plasma filter unit is extremely dirty extremely dilute a mild synthetic laun dry detergent low alkalinity or isotope detergent to 15 times the standard concentration and allow the plasma filter unit to soak in it 2 Gently move up and down and to the right and left A soft sponge can also be used to wipe the surface 3 Rinse with clean water 4 Shake the plasma f...

Страница 17: ...nts the two ends of its lower side as well as two center points of the lower side as shown in the figure to close it If after cleaning the dust collection unit the operation indicator lamp and the timer indicator lamp flash during Air Cleaning please ensure that the unit is not damp and that the intake grille is properly closed If after having checked that the unit is fully dry and that the intake...

Страница 18: ...aned once every six months Please only install filters that are licensed by our company Regarding storage and care of the filter please avoid exposing it to high temperatures and high humidity Also use it as soon as possible after opening its packaging Hook Filter case Filter Case Hook Hook Hook Click When removing the filter please follow these steps backwards How to install or remove the Air cle...

Страница 19: ...rted fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat for a higher setting During Heating operation the unit will temporarily stop opera tion between 7 and 15...

Страница 20: ...s If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Autom...

Страница 21: ...used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip on...

Отзывы: