- (01 - 18) -
W
AL
L M
OU
NT
ED T
YP
E
A
SU
24
C
L1
W
AL
L M
OU
NT
ED T
YP
E
A
SU
24
C
L1
JUMPER WIRE SETTING
Auto restart setting (JM5)
z
.
(
Factory setting)
JM 5
Auto restart
Connect
Validity
Disconnect
Invalidity
Room temperature correction setting (JM6, JM7)
z
(
Factory setting)
JM 6
JM 7
Room temperature correction
Cooling
Drying
Connect
Connect
Standard
Disconnect
Connect
Slightly lower control
Connect
Disconnect
Slightly lower control
Disconnect
Disconnect
Lower control
Remote controller signal code setting (JM8, JM10)
z
(
Factory setting)
Jumper wire
Remote controller
signal code
JM 8
JM 10
Connect
Connect
A
Disconnect
Connect
B
Connect
Disconnect
C
Disconnect
Disconnect
D
REMOTE CONTROLLER SIGNAL CODE SETTING
Use the following steps to select the signal code of the remote controller.
(Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.)
Press the START/STOP button until only the clock is displayed on the remote controller display.
1.
Press the MODE button for at least five seconds to display the current signal code (initially set to
2.
).
Press the SET TEMP. (
3.
) (
) button to change the signal code between → → →
.
Match the code on the display to the air conditioner signal code.
Press the MODE button again to return to the clock display. The signal code will be changed.
4.
If no buttons are pressed within 30 seconds after the signal code is displayed, the system returns to the original clock
display. In this case, start again from step 1.
The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a
signal code other than signal code A, reset the signal code after replacing the batteries.
If you do not know the air conditioner signal code setting,try each of the signal codes ( → → → .) until you
find the code which operates the air conditioner.
Содержание Inverter Halcyon AOU24CL1
Страница 1: ...AIR CONDITIONER Wall Mounted type INDOOR OUTDOOR ASU24CL1 AOU24CL1 DESIGN TECHNICAL MANUAL ...
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASU24CL1 DTR_AS046E_02 2010 12 02 ...
Страница 23: ...2 OUTDOOR UNIT SINGLE TYPE AOU24CL1 DTR_AO068E_02 2010 12 02 ...
Страница 28: ... 02 04 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 WIRING DIAGRAMS 444 MODEL AOU24CL1 ...
Страница 33: ... 02 09 OUTDOOR UNIT AOU24CL1 OUTDOOR UNIT AOU24CL1 SOUND LEVEL CHECK POINT 88888 39 3 8 in 1m ...