Fujitsu Inverter Halcyon AOU12R2 Скачать руководство пользователя страница 8

En-7

TIMER OPERATION

To Use the ON timer or OFF timer

1

Press the START / STOP button (Fig. 6 

M

).

(if the unit is already operating, proceed to step 2).

The indoor unit's OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Press the TIMER button (Fig. 6 

K

) to select the OFF

timer or ON timer operation.

Each time the button is pressed the timer function changes in the following
order:

The indoor unit's green TIMER lamp (Fig. 3 

6

) will light.

3

Use the SET TEMP. / SET TIME buttons (Fig. 6 

I

) to

adjust the desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue
for about five seconds).

 

,

 button: Press to advance the time.

 

-

 button: Press to reverse the time.

About five seconds later, the entire display will reappear.

To Use the Program Timer

1

Press the START / STOP button (Fig. 6 

M

).

(if the unit is already operating, proceed to step 2).

The indoor unit's OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON Timer or OFF Timer” to set the desired
mode and times.
About three seconds later, the entire display will reappear.
The indoor unit's TIMER Indicator Lamp (green) (Fig. 3 

6

) will light.

3

Press the TIMER button (Fig. 6 

K

) to select the

PROGRAM timer operation (OFF   ON or OFF 

 ON

will display).

The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.

● 

The program timer will begin operation. ( If the ON timer has been

selected to operate first, the unit will stop operating at this point).

About five seconds later, the entire display will reappear.

About the Program Timer

The program timer allows you to integrate OFF timer and ON timer operations in
a single sequence. The sequence can involve one transition from OFF timer to
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Control Unit's
Display (OFF 

 ON or OFF 

 ON ).

One example of Program timer use might be to have the air conditioner
automatically stop ( OFF timer ) after you go to sleep, then start ( ON timer)
automatically in the morning before you arise.

      RESET               OFF             ON

  PROGRAM (OFF      ON, OFF      ON)

To Cancel the Timer

Use the TIMER button to select “TIMER
RESET.”
The air conditioner will return to normal
operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation while
the Timer is Operating

Press the START / STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the
timer setting wait until the entire display
reappears, then press the appropriate
buttons to change the operating condition
desired.

To Cancel the Timer

Use the TIMER button to select “TIMER
RESET.”
The air conditioner will return to normal
operation.

To Change the Timer Settings

1. Follow the instructions given in the

section "To Use the ON Timer or OFF
Timer" to select the timer setting you
wish to change.

2. Press the TIMER button to select either

OFF 

 ON or OFF 

 ON.

To Stop Air Conditioner Operation while
the Timer is Operating

Press the START / STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the
timer setting wait until the entire display
reappears, then press the appropriate
buttons to change the operating condition
desired.

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time, see page 4.

Содержание Inverter Halcyon AOU12R2

Страница 1: ...or Unit ASU9R2 ASU12R2 Outdoor Unit AOU9R2 AOU12R2 KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO HEAT COOL MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE ...

Страница 2: ... drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least one metre away from either the in door or outdo...

Страница 3: ...op the test operation mode press the START STOP button to stop the air conditioner T Remote Control Unit Display Fig 8 U Transmit Indicator V Clock Display W Operating Mode Display X Timer Mode Display Y Fan Speed Display Z Temperature Set Display Timer Set Indicator Temperature Set Indicator Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO ...

Страница 4: ... period of operation When the set time is reached the unit automatically turns off SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation MILDEW RESISTANT FILTER The AIR FILTER has been treated to...

Страница 5: ... the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 6 R Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME buttons Fig 6 I to adjust the clock to the ...

Страница 6: ...n Speed Press the FAN CONTROL button Fig 6 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the air issued from the indoor unit is low Co...

Страница 7: ...utes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operatio...

Страница 8: ... single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditio...

Страница 9: ...s elapsed at which time the air conditioner automatically turns off SLEEP timer setting 4 F 6 F 8 F 30 minutes 2 F 1 hour 1 hour 30 minutes Set time Set time 1 hour 2 F 4 F Unlike other timer functions the SLEEP timer is used to set the length of time until air conditioner operate is stopped To Use the SLEEP Timer While the air conditioner is operating or stopped press the SLEEP button Fig 6 N The...

Страница 10: ...ed outside the range 1 3 for more than 30 minutes they will automatically return to position 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 O Each time the button is pressed the air direction range will change as follows...

Страница 11: ... very low speeds MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated with the controls ...

Страница 12: ... unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When cleaning the unit s body do not use water hotter than 108 F harsh abrasive cleansers or volatile agents like benzene or thinner Do not expose the unit body to liquid insecticides or hairsprays When shutting down the unit for one month or more first allow the fan mod...

Страница 13: ...oner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will st...

Страница 14: ...ith a Microcomputer controlled Auto matic Defrosting function If frost forms the air condi tioner will temporarily stop and the defrosting circuit will operate briefly for about 7 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp red will flash Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring t...

Страница 15: ...5 F 88 F or less Temperature and Humidity Range If the unit is used for long pe riods under high humidity conditions condensation may form on the surface of the in door unit and drip onto the floor or other objects underneath About 80 or less About 50 or less Indoor Humidity Outdoor temperature 68 F or obove Outdoor temperature below 68 F ...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: