background image

En-15

SLEEP TIMER OPERATION

About the SLEEP timer

To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modi

fi

 es the temperature setting in 

accordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.

During Cooling/Dry operation:

When the SLEEP timer is set, the temperature setting is auto-
matically raised 

˚

F

 every 1 hour. When the temperature setting 

is raised a total of 

˚

F

, the temperature setting at that time is 

maintained until the set time elapses, at which time the air con-
ditioner automatically turns off.

SLEEP timer setting

During Heating operation:

When the SLEEP timer is set, the temperature setting is 
automatically lowered 

˚

F

 every 30 minutes. When the temper-

ature setting is lowered a total of 

˚

F

, the temperature setting at 

that time is maintained until the set time elapses, at which time 
the air conditioner automatically turns off.

SLEEP timer setting

1

  Press the TIMER SETTING button 

 

.

 

” will be 

fi

 rstly displayed 

fl

 ashing. 

Press the SELECT button 

 to select “

”.

 

Press the NEXT button 

 

.

2

  Press the SELECT button 

 to set the OFF time.

 button: 

0.5H

1H

2H

3H

5H

7H

9H

 button: 

0.5H

7H

5H

3H

2H

1H

9H

3

  Press the SEND button 

 

.

You can set the OFF TIMER to any time you want when you go to sleep.
The product adjusts the temperature to make it suitable for sleeping, which helps you sleep comfortably.
Once you set the time you want, you can easy set the timer to run from the next time, simply by pressing the SLEEP button 

 once.

To use the SLEEP timer

1

  Press the SLEEP button 

 while “

” is 

displayed.

2

  “

” will disappear from the display.

To cancel the SLEEP timer

 

When you press the SLEEP button

 

 

while 

 

is no longer 

displayed, the SLEEP TIMER you 

set last time will be set again.

● 

The WEEKLY TIMER, ON/OFF 

TIMER (program timer) and SLEEP 

TIMER cannot be combined.

(30 min)

(30 min)

˚

F

˚

F

˚

F

30 
minutes

˚

F

1 hour

1 hour 

30 minutes

Set time

Set temp

Set time

1 hour

˚

F

˚

F

Set temp

To Stop Air Conditioner Operation 

while the Timer is Operating

Press the START/STOP button 

.

Flashing the “

”.

If you want to cancel the setting midway, please press the TIMER 
SETTING button 

 instead of pressing the SEND button 

.

9319356051_OM.indb   15

9319356051_OM.indb   15

12/5/2011   3:25:41 PM

12/5/2011   3:25:41 PM

Содержание Inverter Halcyon 9319356051

Страница 1: ... DE FUNCIONAMIENTO AIR CONDITIONER Compact Wall Mounted Type KEEP THIS OPERATING MANUAL FOR FUTURE REFERENCE CONSERVER CE MANUEL D UTILISATION POUR POUVOIR LE CONSULTER ULTÉRIEUREMENT CONSERVE ESTE MANUAL DE FUNCIONAMIENTO PARA FUTURA REFERENCIA PART NO 9319356051 ...

Страница 2: ...not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the indoor unit for exten...

Страница 3: ...ss ones ENERGY SAVING PROGRAM MIN HEAT OPERATION OUTDOOR UNIT LOW NOISE OPERATION WEEKLY TIMER ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Energy saving and Comfortable function INVERTER At the start of operation large amount of power is used to bring the room quickly to the desired temperature Afterward the air conditioner automatically switches to a low power set ting for economic ...

Страница 4: ...CONOMY OPERATION and MIN HEAT OPERATION is operating INDOOR UNIT Drain Hose Air Cleaning Filter Open the Intake Grille See page 20 Air Filter Airflow Direction Louver Remote controller Batteries Air cleaning filters Remote controller holder Tapping screws Accessories of the indoor unit Human Sensor Open Panel Right Left Louver behind Airflow Direction Louver It opens at the same time of operation ...

Страница 5: ...or Signal transmission indicator SWING indicator FAN speed indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual opera tion however the display will only show those indicators appropriate to the current operation After the button is pressed on remote controller only the operated part is displayed until the transmission of the sig...

Страница 6: ...reversed in 1 minute increments hold the buttons depressed to change the time quickly in 10 minute increments 4 Press the SEND button This completes the time setting and starts the clock Press the SEND button when you are close to the main unit If you do so when far from the main unit the signal may not get properly sent and the settings may not get properly configured To Use the Remote Controller...

Страница 7: ...nds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the temperature setting the fan speed becomes slower When the room temperature is close to the set temperature the...

Страница 8: ...ry low frost may form on the outdoor unit and its performance may be reduced In order to remove such frost the air conditioner will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator Lamp will flash and the Heat operation will be interrupted After the start of Heating operation it takes some time before the room gets warmer Cooling...

Страница 9: ...e Remote Controller s SET button to adjust the vertical airflow louvers Attempting to move them man ually could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again During use of the Cooling and Dry modes do not set the Airflow Direc tion Louvers in the Heating range 4 7 for many hours since water vapor may condense near the outlet...

Страница 10: ...not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation If ENERGY SAVING is set If ENERGY SAVING is off ENERGY SAVING PROGRAM Since the human sensor detects infrared light given out by people there may be cases where this detection is incorrect Situations in which the sensor will detect no people...

Страница 11: ...Air Conditioner operation before performing this procedure To use POWERFUL Operation Press the POWERFUL button Only as for this button operation the beep sound is different from the others Powerful operation start Beep 3 times Pi Pi Pi Others Beep 2 times Pi Pi To stop POWERFUL Operation Press the POWERFUL button again Normal operation begins About the POWERFUL Operation Cooling Dry Powerful Opera...

Страница 12: ...ISE Operation Press the OUTDOOR UNIT LOW NOISE button LOW NOISE appears on the Remote Controller display To stop the OUTDOOR UNIT LOW NOISE Operation Press the OUTDOOR UNIT LOW NOISE button LOW NOISE disappears from the Remote Controller display Normal operation begins OUTDOOR UNIT LOW NOISE OPERATION OUTDOOR UNIT LOW NOISE Operation mode reduces the noise level of the outdoor unit by suppressing ...

Страница 13: ... time you set OFF TIMER The air conditioner will stop at the time you set Before using the timer function be sure that the Remote Controller is set to the cor rect current time Press the ON OFF button while is not displayed to set the ON OFF TIMER again for the time you set last time You cannot combine WEEKLY TIMER ON OFF TIMER PROGRAM TIMER and SLEEP TIMER or will be flashing To cancel the ON tim...

Страница 14: ...o ON timer or from ON timer to OFF timer within a 24 hour period Before using the timer function be sure that the Remote Controller is set to the cor rect current time Press the ON OFF button while is not displayed to set the ON OFF TIMER again for the time you set last time Only run operation once with the OFF TIMER and ON TIMER combined Either OFF ON or ON OFF once Out of OFF TIMER and ON TIMER ...

Страница 15: ...button will be firstly displayed flashing Press the SELECT button to select Press the NEXT button 2 Press the SELECT button to set the OFF time button 0 5H 1H 2H 3H 5H 7H 9H button 0 5H 7H 5H 3H 2H 1H 9H 3 Press the SEND button You can set the OFF TIMER to any time you want when you go to sleep The product adjusts the temperature to make it suitable for sleeping which helps you sleep comfortably O...

Страница 16: ... use the ON OFF together with the SLEEP timer If you want to run the product on WEEKLY TIMER after the time is up after using the ON OFF Timer Program Timer or SLEEP Timer within the WEEKLY TIMER you need to set the WEEKLY TIMER again See page 19 Using in these cases of WEEKLY timer Example of how to set the timer 2 You can specify a given temperature in the ON setting in WEEKLY TIMER You can set ...

Страница 17: ...ing the SELECT button select operation with the ON Timer OFF Timer or without a timer To operate without a timer 1 Press the NEXT button to go back to step 2 and config ure the next setting 2 Press the SEND button to finish Press the NEXT button WEEKLY TIMER OPERATION Flashing the The program and day of the week will be flashing Flashing the or Program 1Week Program Monday Program Tuesday Program ...

Страница 18: ...IMER OPERATION The time indicator will be flashing The temperature indicator will be flashing If you want to cancel the setting midway please press the TIMER SETTING button instead of pressing the SEND button 4 Press the SELECT button to set the desired ON time or OFF time If you selected OFF in step 3 1 Press the NEXT button to go back to step 2 and configure the next setting 2 Press the SEND but...

Страница 19: ...You cannot combine WEEKLY TIMER ON OFF TIMER PROGRAM TIMER and SLEEP TIMER WEEKLY TIMER OPERATION 1 Press the TIMER SETTING button Firstly since will be flashing Press the NEXT button 2 Check the program the day and the time with the SELECT button 3 Press the TIMER SETTING button to return to the regular screen To cancel the WEEKLY timer Check the schedule ...

Страница 20: ...iency and increasing noise During periods of normal use the Air Filters should be cleaned every 2 weeks 3 Replace the air filters Align the sides of the air filter with the panel and push in fully making sure the 2 lower tabs are returned properly to their holes in the panel Air filter tabs 2 places Close the Intake Grille 1 Release the grille stay Grille stay 2 Close the intake grille Tab of 3 pl...

Страница 21: ...t in the opened package Generally the filters should be exchanged about every 3 months Please buy dedicated air cleaning filters UTR FA16 Sold separately to exchange the used dirty air cleaning filter NEGATIVE AIR IONS DEODORIZING FILTER light blue 1 sheet The filter should be exchanged about every 3 years so as to maintain the deodorizing effect Filter frame is not a one off product Please buy de...

Страница 22: ... indoor unit This smell is the re sult of room smells furniture tobacco etc which have been taken into the indoor unit Mist or steam is emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in condensation and misting During Heating operation the outdoor un...

Страница 23: ...g produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recir culating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under condition...

Страница 24: ......

Отзывы: