OPERATING TIPS

During heating mode:

Set the thermostat to a temperature setting 
that is higher than the current room tem-
perature. The heating mode will not operate 
if the thermostat is set lower than the actual 
room temperature.

During cooling/dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room 
temperature. The cooling and dry modes 
will not operate if the thermostat is set 
higher than the actual room temperature 
(in cooling mode, the fan alone will ope-
rate).

During fan mode:

You can not use the unit to heat and cool 
your room.

HEAT*:

 

  Use to warm your room.

 

  When heating mode is selected, the air conditioner will operate at very low 

fan speed for about 3 to 5 minutes, after which it will switch to the selected 
fan setting. This period of time is provided to allow the indoor unit to warm 
up before beginning full operation.

 

  When the room temperature is very low, frost may form on the outside unit, 

and its performance may be reduced. In order to remove such frost, the unit 
will automatically enter the defrost cycle from time to time. During automatic 
defrosting operation, the heat operation will be interrupted.

 

  After the start of heating operation, it takes sometime before the room gets 

warmer.

COOL:

 

  Use to cool your room.

DRY:

 

  Use for gently cooling while dehumidifying your room.

 

  You cannot heat the room during dry mode.

 

  During dry mode, the unit will operate at low speed; in order to adjust room 

humidity, the indoor unit’s fan may stop from time to time. Also, the fan may 
operate at very low speed when adjusting room humidity.

 

  The fan speed cannot be changed manually when dry mode has been se-

lected.

FAN:

 

  Use to circulate the air throughout your room.

 

Room temperature is higher than the de ned temperature in temperature 
setting  Cooling mode or dry mode

 

 

Room temperature is close to the de ned temperature in temperature set-
ting  Determined by outdoor temperature

 

  Room temperature is lower than the de ned temperature in temperature 

setting  Heating mode 

Cooling or Dry

Heating

Determined by 
outdoor temperature 

Defi ned tem-
perature in 
temperature 
setting 

AUTO [in HEAT & COOL (Reverse Cycle) model]: 

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

 

When AUTO (automatic changeover) is selected, the air conditioner selects the appropriate operation mode (cooling or 
heating) according to your room’s present temperature.

  When AUTO (automatic changeover) operation  rst selected, the fan will operate at low speed for about a few minute, 

during which time the indoor unit detects the room conditions and selects the proper operation mode.

  When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor opera-

tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the 
air conditioner will once again select the appropriate operation (heating, cooling) to adjust the temperature to the value 
set in the thermostat.

  If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, 

FAN).

AUTO (in COOLING model) : 

 

When AUTO (automatic changeover) operation  rst selected, the fan will operate at very low speed for about a few minutes, 
during which time the indoor unit detects the room conditions and selects the proper mode.

 

Room temperature is higher than the de ned temperature in temperature 
setting  Cooling mode or dry mode

 

  Room temperature is close to or lower than the de ned temperature in 

temperature setting  Monitor operation

 

When the indoor unit has adjusted your room’s temperature to near the temperature setting, it will begin monitor opera-
tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, 
the indoor unit will once again select the appropriate operation (cooling) to adjust the temperature to the value set in the 
temperature setting.

 

If the mode automatically selected by the unit is not what you wish, select one of the mode operation (COOL, DRY, 
FAN).

Cooling mode 
or Dry mode

Monitor operation

Defi ned tem-
perature in 
temperature 
setting 

Mode Operation

9378589063_OM_EN.indb   18

3/15/2012   1:55:34 PM

Содержание Inverter AUTG54LR

Страница 1: ...KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED PART NO 9378589063 Indoor Unit AUTG54LR AIR CONDITIONER Cassette Type OPERATING MANUAL ...

Страница 2: ...orage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator ns Operate only with air lters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least 1m away from either the indoor or outdoor units Avoid installing the air conditioner near a replace or other heating apparatus When installing t...

Страница 3: ...WIRED REMOTE CONTROLLER The wired remote controller allows convenient control of in door unit operation WIRELESS REMOTE CONTROLLER OPTION The optional wireless remote controller can be used When you use remote controller there are following different points as compared with using wired remote controller The additional function for wireless ones SLEEP timer TIMER 10 C HEAT operation And you can use...

Страница 4: ...s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Please press the button at Filter Reset 8 OPERATION indicator lamp green 9 TIMER indicator lamp orange TIMER Indicator lamp lights when the timer is set from wireless remote con troller 0 ECONOMY indicator lamp green ECONOMY indicator lamp lights in fol lowing operations ECONOMY operation...

Страница 5: ...utton 1 D MAINTENANCE FILTER RESET button 1 E Operation lamp F Timer and Clock indicator G Operation mode indicator H Fan speed indicator I Operation lock indicator J Temperature indicator K Function indicator Defrost indicator Thermo sensor indicator ECONOMY indicator Vertical swing indicator Filter indicator 1 1 This function cannot be used Please also see the operating manual of the op tion whe...

Страница 6: ...d the selected day Press the SET TIME buttons to set the current time Press repeatedly to adjust the current time in 1 minute incre ments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK ...

Страница 7: ...ill be set to AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY operation For details on the function refer to page 14 To start stop operation To set the operation mode Operation mode setting Room temperature setting Fan speed setting ECONOMY operation Instructions relating to heating are applicab...

Страница 8: ...r selection OPERATION Child lock function Press the DAY DAY OFF button and TIMER SET button simul taneously for 2 seconds or more to activate the child lock func tion and lock all of the buttons on the remote controller except the START STOP button SET TEMP buttons MODE button and FAN button Press the buttons again for 2 seconds or more to deactivate the child lock function When the child lock fun...

Страница 9: ...onditioner operation stops after the set time has passed The timer can be set up to 24 hours in advance ON timer See page 9 Use this timer function to start air conditioner operation The timer operates and air conditioner operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 10 Use this timer function to set operating times for each day...

Страница 10: ...DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more To delete the operating time If the TIMER DELETE button is pressed dur ing steps 3 or 4 the operating time for the selected day will be deleted If all the days ...

Страница 11: ... button for 2 seconds or more to com plete the DAY OFF setting 2 4 3 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day s...

Страница 12: ...the SET BACK con rmation display SET BACK ex When setting all days together Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings 24 C 24 C 28 C SET BAC...

Страница 13: ...rst minute after beginning operation air ow will be horizontal 1 the air direction cannot be adjusted during this period Horizontal air direction adjustment The function cannot be used Attempting to move up down air direc tion aps manually could result in im proper operation in this case stop op eration and restart The louvers should begin to operate properly again When used in a room with infants...

Страница 14: ...MY button again The ECONOMY indicator will go out Normal operation begins About ECONOMY Operation At the maximum output ECONOMY operation is approximately 70 of normal air conditioner operation for cooling and heating If the room is not cooled or heated well during ECONOMY operation select normal operation During the monitor period in the AUTO mode the air conditioner operation will not change to ...

Страница 15: ...r parts of the unit to dry thoroughly in advance by operating the unit in fan mode for half a day 3 Clean the air lter Remove the dust from the air lters by vacuuming or washing them After washing allow the air lters to dry thoroughly in an area protected from sunlight 4 Re attach the air filters to the intake grille 1 Replace the air lter into its holder 2 Make sure that the air lter makes contac...

Страница 16: ... of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During heating operation the outdoor unit s fan may stop and steam may be...

Страница 17: ... operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuf cient heating performance is being pro duced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room b...

Страница 18: ...rature setting Heating mode Cooling or Dry Heating Determined by outdoor temperature Defined tem perature in temperature setting AUTO in HEAT COOL Reverse Cycle model Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle When AUTO automatic changeover is selected the air conditioner selects the appropriate operation mode cooling or heating according to your room s pr...

Страница 19: ...may become warm but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped it is not a malfunction During use of the heating mode the outdoor unit will occa sionally commence the defrost operation for brief periods During the defrosting operation if the user sets the indoor unit for heating again the defrosting mode will continue and the heating operatio...

Страница 20: ......