background image

HEAT & COOL MODEL
(REVERSE CYCLE)

AIR CONDITIONER

Duct Type

Indoor Unit

ARTG09LL
ARTG12LL
ARTG18LL

OPERATING MANUAL

KEEP THIS MANUAL FOR FUTURE REFERENCE

P/N9374379439

9374379439_OM_1.indd   1

9374379439_OM_1.indd   1

3/12/2553   15:43:03

3/12/2553   15:43:03

Содержание Inverter ARTG09LL

Страница 1: ...HEAT COOL MODEL REVERSE CYCLE AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P N9374379439 ...

Страница 2: ...n the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electroni...

Страница 3: ...ff timed opera tion for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days TEMPERATURE SET BACK TIMER Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings REMOVABLE AIR FILTER The indoor unit s air...

Страница 4: ...tion and Swing Button 2 D MAINTENANCE FILTER RESET Button 1 E Operation Lamp F Timer and Clock Display G Operation Mode Display H Fan Speed Display I Operation Lock Display J Temperature Display K Function Display Defrost Display Thermo Sensor Display ECONOMY Display Vertical Swing Display 3 Filter Display 1 1 3 These functions cannot be used Please also see the operating manual of the option when...

Страница 5: ...nd the selected day Press the SET TIME buttons to set the current time Press repeatedly to adjust the current time in 1 minute incre ments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK...

Страница 6: ...peration mode If DRY is selected the fan speed will be set to AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY OPERA TION For details on the function refer to page 11 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To start stop operation To set the operation...

Страница 7: ...nsor selection OPERATION Child lock function Press the DAY DAY OFF button and TIMER SET button simultaneously for 2 seconds or more to activate the child lock function and lock all of the buttons on the remote controller except the START STOP button SET TEMP buttons MODE button and FAN button Press the buttons again for 2 seconds or more to deactivate the child lock function When the child lock fu...

Страница 8: ...air conditioner operation The timer operates and air conditioner operation stops after the set time has passed The timer can be set up to 24 hours in advance ON timer See page 7 Use this timer function to start air conditioner operation The timer operates and air conditioner operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 8 Use th...

Страница 9: ...e DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more To delete the operating time If the TIMER DELETE button is pressed dur ing steps 3 or 4 the operating time for the selected day will be deleted If all the day...

Страница 10: ... button for 2 seconds or more to com plete the DAY OFF setting 2 4 3 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day s...

Страница 11: ...r the SET BACK confirmation display SET BACK ex When setting all days together Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings 24 C 24 C 28 C SET ...

Страница 12: ... will be reduced lowering operating efficiency and increasing noise CAUTION ECONOMY OPERATION Begin Air Conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY display will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY display will go out Normal operation begins About ECONOMY ...

Страница 13: ... the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensa tion and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to the Automatic Defrosting operation 14 Airflow is weak or stops When Heating operation is started fan speed is temporarily very low to al...

Страница 14: ... blocked Did you adjust the room temperature settings thermostat cor rectly Is there a window or door open In the case of Cooling operation is a window allowing bright sun light to enter Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for QUIET operation If the problem persists af...

Страница 15: ...end you use this air conditioner in conjunction with another type of heating appliance Heat pump air conditioners heat your entire room by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of...

Страница 16: ...switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the outdoor temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the heat operati...

Страница 17: ... when multiple units are used simultaneously for heating it is recommended that they be used in conjunction with other auxiliary space heaters as required Seasonal and outdoor temperature conditions the structure of the rooms and the number of persons present may also result in differences of operating efficiency We recommend that you try various operating patterns in order to confirm the level of...

Страница 18: ...NOTE ...

Страница 19: ...NOTE ...