Содержание Halcyon AOU12RQ

Страница 1: ...ASU9RQ ASU12RQ AOU9RQ AOU12RQ ...

Страница 2: ... Fig 6 Remote Control Unit H MASTER CONTROL button I SET TEMP SET TIME buttons J Signal Transmitter K TIMER button L FAN CONTROL button M START STOP button N AIR CLEAN button O SET button P SWING button Q ACL button R TIME ADJUST button Rear side Fig 7 S TEST RUN Touch the two metal contacts with a metallic object to send the signal to perform a test run Perform a test run only when installing the...

Страница 3: ...ROL button is used to select QUIET the unit begins super quiet operation the indoor unit s air flow is reduced to produce quieter operation AIR CLEANING MODE Relies on the air conditioner s power to quickly purify the air in the room ELECTRONIC AIR CLEAN FILTER Install for use inside of the dust collection unit For details on how to install the filter please refer to page 15 Electrical power is us...

Страница 4: ... the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 6 R Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME buttons Fig 6 I to adjust the clock to the ...

Страница 5: ...n Speed Press the FAN CONTROL button Fig 6 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the air issued from the indoor unit is low Co...

Страница 6: ...utes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operatio...

Страница 7: ... stop the operation install the intake filter and then use the START STOP button to restart the operation Use the FAN CONTROL button to change the fan speed Refer to page 6 The plasma filter unit operates most effectively at the highest fan speed The air clean indicator lamp will flash to inform you that the periodic cleaning of the plasma filter unit is required Refer to page 14 If you wish to st...

Страница 8: ...ngle sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditioner...

Страница 9: ...During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accon dance with the time setting When the set time has elapsed the air conditioner completely stops During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 2 F every...

Страница 10: ...ted outside the range 1 3 for more than 30 minutes they will automatically return to position 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 O Each time the button is pressed the air direction range will change as follow...

Страница 11: ...ANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the AIR CLEANER RESET MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the AIR CLEANER RESET MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated ...

Страница 12: ...ither with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to accumulate on the Air Filter air flow will be reduced lowering operating efficiency and in creasing noise During periods of normal use the Air Filters should be cleaned every two w...

Страница 13: ... cleaning the air filter on page 12 handle 2 Remove the dust collection unit Securely grasp the dust collection unit by the handle and pull it out as shown by the arrow The above figure is only for reference so the intake grille is not included 3 Wash with water and dry 1 Soak the plasma filter unit in warm water 104 to 122 F for 10 to 15 minutes If the plasma filter unit is extremely dirty extrem...

Страница 14: ...o flash the dust collection unit may be damaged Please consult an authorised dealer to obtain a replacement Align the two ends of the dust collection unit with the guide rail and slide in Slide in until it clicks Guide rail Click Click Please ensure that the intake grille is closed properly Cleaning the dust collection unit 4 Install the unit The above figure is only for reference so the intake gr...

Страница 15: ...only possible if the filter is cleaned once every six months Please only install filters that are licensed by our company Regarding storage and care of the filter please avoid exposing it to high temperatures and high humidity Also use it as soon as possible after opening its packaging Hook Filter case Filter Case Hook Hook Hook Click When removing the filter please follow these steps backwards Ho...

Страница 16: ...bacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic De...

Страница 17: ...use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the Power Supply Plug reconnect it and then use the Remote Control Unit to resume operation OPERATING TIPS Microcomputer controlled Automatic Defrosting When using the Heating mode under conditions of low outdoor temperature and high humidity frost may form on the outdoor unit resu...

Страница 18: ...5 F 88 F or less Temperature and Humidity Range If the unit is used for long pe riods under high humidity conditions condensation may form on the surface of the in door unit and drip onto the floor or other objects underneath About 80 or less About 50 or less Indoor Humidity Outdoor temperature 68 F or obove Outdoor temperature below 68 F ...