3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ASHG07KPCE
ASHG09KPCE
ASHG12KPCE
Heating
POWERFUL
1,370
1,470
HIGH
1,300
1,400
MED+
1,190
1,280
MED
1,080
1,140
LOW
930
930
QUIET
700
700
Cool air prevention
630
630
S-LOW
580
580
Cooling/Fan
POWERFUL
1,370
1,470
HIGH
1,300
1,400
MED
1,080
1,140
LOW
850
890
QUIET
650
630
Soft quiet
580*
1
580*
1
S-LOW
580*
2
580*
2
Dry
X zone: 650
J zone: 650
X zone: 650
J zone: 650
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan